Dataset related to article "Clinical performance of Xpert Bladder Cancer (BC) Monitor, a mRNA‐based urine test, in active surveillance (AS) patients with recurrent non‐muscle‐invasive bladder cancer (NMIBC): results from the Bladder Cancer Italian Active Surveillance (BIAS) project"
- Rodolfo Hurle1
- Paolo Casale1
- Alberto Saita1
- Piergiuseppe Colombo1
- Grazia Maria Elefante1
- Giovanni Lughezzani1
- Vittorio Fasulo1
- Marco Paciotti1
- Luigi Domanico1
- Giulio Bevilacqua1
- Davide Maffei1
- Pietro Diana1
- Nicola Frego1
-
Maria Teresa Sandri1
- Federica Maura1
- Emanuela Morenghi1
- Nicolò M Buffi2
- Giorgio Guazzoni2
-
Massimo Lazzeri1
- 1. IRCCS Humanitas Research Hospital, via Manzoni 56,20089 Rozzano (Mi) - Italy
- 2. IRCCS Humanitas Research Hospital, via Manzoni 56,20089 Rozzano (Mi) - Italy AND Humanitas University, Department of Biomedical Sciences, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele – Milan, Italy
Description
This record contains raw data related to article “ "Clinical performance of Xpert Bladder Cancer (BC) Monitor, a mRNA‐based urine test, in active surveillance (AS) patients with recurrent non‐muscle‐invasive bladder cancer (NMIBC): results from the Bladder Cancer Italian Active Surveillance (BIAS) project""
The paper investigates the clinical performance of a new mRNA-based urine test, aiming to avoid unnecessary follow-up cystoscopy in patients under active surveillance (AS) for recurrent NMIBC. This is a prospective cohort study enrolling patients with history of low-grade (LG) NMIBC, who developed a recurrence during the follow-up and underwent AS. Their urinary samples were analyzed by Xpert BC Monitor (Cepheid, Sunnyvale, CA, USA). The primary endpoint was to investigate if Xpert BC Monitor could avoid unnecessary cystoscopy during the follow-up period. Its sensitivity, specificity, PPVs and NPVs were calculated. A cutoff of 0.4 “linear discriminant analysis” (LDA) was optimized for the AS setting. The cohort consisted of 106 patients with a mean age of 72±9.52 and a median follow-up from AS start of 8.8 (range 0–56.5) months. No statistically significant difference was found for the mean age, smoker status, lesion size, and number of lesions with a cutoff of 0.4. Of 106 patients, 22 (20.8%) were deemed to require treatment because of cystoscopic changes in size and/or number of lesions during the follow-up period. Using a cutoff value of < 0.4, 34 (33.7%) cystoscopies could be avoided due to low LDA value, missing 2/22 (9%) failures, none with high-grade (HG) NMIBC. Further research on larger population remains mandatory before its clinical use.Xpert BC Monitor seems to be a reliable assay, which might avoid unnecessary cystoscopies without missing HG NMIBC when its cutoff is optimized for the AS setting.
Files
Additional details
Related works
- Is supplement to
- 10.1007/s00345-019-03002-3 (DOI)