Limits of slenderness ratios for URM walls: proposal for EC8-Part 1 - Background document for the masonry chapter in EC8 Part 1
Description
This document puts forward a proposal for slenderness limits to be used for unreinforced masonry (URM) walls. If these slenderness limits are met, out-of-plane safety checks do not need to be explicitly conducted.