Published February 15, 2019
| Version v1
Journal article
Open
The review of the water mist fire extinguishing technology
Authors/Creators
- 1. Jiangsu University of Science and Technology
- 2. Ogarev Mordovia State University
Description
Due to the signing of the Montreal Convention, people have been looking for alternatives to the halon fire extinguishing system. The water mist is widely concerned because of its unique advantages. Many scholars have conducted extensive research on water mist fire extinguishing technology. This paper makes a review of the development and research results of the water mist.
Files
Chen L., Wang L., Yankin V., Neyasov A. .pdf
Files
(295.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:98764e9c84d7498116e44b015738c34c
|
295.6 kB | Preview Download |
Additional details
Identifiers
Related works
- Is compiled by
- 2414-2948 (ISSN)
References
- Molina, M. J., & Rowland, F. S. (1974). Stratospheric Sink for Chlorofluoromethanes: Chlorine Atom Catalyzed Destruction of Ozone. Nature, (249). 810-812.
- Mawhinney, J. R., Dlugogorski, B. Z., & Kim, A. K. (1994). A closer look at the fire extinguishing properties of water mist. Fire Safety Science, 4, 47-60.
- Mawhinney, J. R., & Richardson, J. K. (1997). A review of water mist fire suppression research and development, 1996. Fire Technology, 33(1), 54-90.
- Mawhinney, J. R., & Back, G. G. (2016). Water mist fire suppression systems. In: SFPE Handbook of fire protection engineering. Springer, New York, NY, 1587-1645.
- Downie, B., Polymeropoulos, C., & Gogos, G. (1995). Interaction of a water mist with a buoyant methane diffusion flame. Fire Safety Journal, 24(4), 359-381.
- Kim, M. B., Jang, Y. J., & Yoon, M. O. (1997). Extinction limit of a pool fire with a water mist. Fire Safety Journal, 28(4), 295-306.
- Ndubizu, C. C., Ananth, R., Tatem, P. A., & Motevalli, V. (1998). On water mist fire suppression mechanisms in a gaseous diffusion flame. Fire Safety Journal, 31(3), 253-276.
- Back Iii, G. G., Beyler, C. L., & Hansen, R. (2000). A quasi-steady-state model for predicting fire suppression in spaces protected by water mist systems. Fire Safety Journal, 35(4), 327-362.
- Kim, M. B., Jang, Y. J., & Yoon, M. O. (1997). Extinction limit of a pool fire with a water mist. Fire Safety Journal, 28(4), 295-306.
- Murakami, M., Kurioka, H., Imazeki, O., Kuwana, H., & Amano, R. (2007). Numerical simulation in effect of compartmentalization with Water Screen (WS) in a tunnel fire. Seisan Kenkyu, 59(3), 313-317.
- Starke, H. (2010, March). Fire suppression in road tunnel fires by a water mist system–results of the solit project. In: Proc. from the 4th Int. Symposium on Tunnel Safety and Security, Frankfurt a/M, 311-321.
- Blanchard, E., Boulet, P., Fromy, P., Desanghere, S., Carlotti, P., Vantelon, J. P., & Garo, J. P. (2014). Experimental and numerical study of the interaction between water mist and fire in an intermediate test tunnel. Fire Technology, 50(3), 565-587.
- Jenft, A., Collin, A., Boulet, P., Pianet, G., Breton, A., & Muller, A. (2014). Experimental and numerical study of pool fire suppression using water mist. Fire safety journal, 67, 1-12.
- Mawhinney, J. R., Dlugogorski, B. Z., & Kim, A. K. (1994). A closer look at the fire extinguishing properties of water mist. Fire Safety Science, 4, 47-60.