SlipAssist - Treadmill Slip-Like Perturbation Dataset With Unassisted and Exoskeleton-Assisted Balance Recovery
Authors/Creators
Description
Overview
SlipAssist is a multimodal human movement dataset for studying gait responses to slip-like disturbances and evaluating wearable systems for perturbation detection and assistance. The dataset combines five laboratory campaigns conducted at the Biomedical Robotic Devices Laboratory, University of Minho, Guimarães, Portugal. Participants walked on a motorized treadmill while an operator delivered brief pulls through a rope attached to the foot. The campaigns cover unassisted walking, walking with a powered knee orthosis, active knee assistance, and active assistance at one hip at a time.
The archive contains 537 source data files and 28 campaign-specific participant records from 24 individuals. Four individuals took part in two campaigns, and a pseudonymous person_id links their records. The recording index contains 624 entries grouped under 150 trial identifiers. An entry can identify a sub-trial, a recording part, or an individual stream stored alongside other streams in the same file. The event index contains 65,830 entries, most of which are heel-contact and toe-off estimates from C4.
Knee flexion–extension is available across all five campaigns. Depending on the campaign, the archive also includes full-body inertial kinematics, processed bilateral lower-limb electromyography, triaxial rope acceleration, controller and actuator telemetry, and auxiliary signals. Machine-readable indexes document the recordings, conditions, signal coverage, and event references.
Experimental design
Participants wore an overhead safety harness and were instructed to walk naturally and recover balance without holding the treadmill rails. The operator selected the timing of each pull visually. In heel-strike-targeted trials, the operator pulled the foot forward shortly after initial contact to produce a backward balance disturbance. C1 also included toe-off-targeted trials, in which the operator pulled the foot backwards near the beginning of swing. All other campaigns targeted heel strike.
In campaigns with annotated pulls, the start of the external pull provides the perturbation reference. Foot-slide onset requires a separate biomechanical measurement. Pull force and displacement were not measured.
Campaigns
C1 — Unassisted walking with matched controls
Eleven participants completed left- and right-foot conditions with intended heel-strike and toe-off targets, at treadmill grades of 0% and 10%. The speed conditions were 1.8 km/h, 5.4 km/h, and a leg-length-normalized speed. Each trial folder contains six sub-trials combining the three speeds with perturbed and unperturbed walking. The archive contains 83 of the 88 planned trials, yielding 498 sub-trial files. The other five trials were discarded because their data were corrupted or did not represent a reliable measurement.
The files contain full-body Xsens kinematics and processed bilateral electromyography envelopes from the rectus femoris, biceps femoris, tibialis anterior, and lateral gastrocnemius. The protocol normalized the envelopes to maximum voluntary contraction. The same approximately 60 Hz export grid also carries auxiliary optical marker, Shimmer, and RespiBAN fields, which are retained as exported. Two auxiliary indexes document their coverage, constant values, and missing intervals.
The event index contains 556 video-derived perturbation-region starts and 490 observed ends. The region end serves as a protocol-specific proxy for return to steady gait. The original acquisition videos are not included.
C2 — Powered knee orthosis and instrumented rope pulls
Five participants walked at 1.4 and 1.6 km/h. The orthosis was worn on the right knee, and the left foot was perturbed near heel strike. The 23 source files cover 20 participant–speed–mode combinations, three of which are stored in two parts.
The recordings include selected Xsens lower-limb kinematics, triaxial acceleration from a rope-mounted inertial sensor, and 223 pull markers on a 100 Hz export grid. There are 107 markers in files labelled passive and 116 in files labelled position. The C2 detector evaluation used 166 perturbations that met its eligibility criteria. The actuator state associated with the position label remains unverified, and the rope-acceleration units are not documented in the export.
C3 — Active knee assistance
One participant wore an active powered knee orthosis on the right knee while the left foot was perturbed near heel strike, at 1.6 km/h. A detector based on a central pattern generator triggered position tracking of a recovery reference trajectory.
The five controller logs are sampled at 100 Hz and contain knee-angle estimates, warning states, trajectory indices, and actuator signals, with actuator positions in degrees. The event index contains 36 warning starts, applying an inclusive 104 s analysis cutoff to T04. The complete T04 source log is included. C3 had no pull-onset sensor, so warning and command timestamps describe events recorded by the controller.
C4 — Unassisted walking with paired knee-angle measurements
Ten participants walked at 1.8 and 3.0 km/h, with pulls targeting heel strike. The four trial blocks followed this fixed order:
T01 — right-foot perturbations at 1.8 km/h
T02 — right-foot perturbations at 3.0 km/h
T03 — left-foot perturbations at 1.8 km/h
T04 — left-foot perturbations at 3.0 km/h
One MATLAB file per participant contains the full-body Xsens and controller streams. The index identifies 47 paired recording parts, with one entry per stream and part. The effective export rates are approximately 60 Hz for Xsens and 261–276 Hz for the controller. A rope-mounted inertial sensor was configured in Xsens MVN as a prop on the perturbed foot and is exported as <Side>FootGeneric_Accel_X/Y/Z. In three left-foot parts, the export labels this prop as right; the protocol side identifies the perturbed foot. Pull onsets are not marked in the exports. The archive indexes 30,384 estimated heel contacts and 33,949 estimated toe-offs derived from Xsens contact flags.
C5 — Active hip assistance
One participant walked at 1.8 km/h with the HANK Research Version exoskeleton, which has actuators at both hips. Pulls targeted heel strike of the right foot in T01, acquired first, and of the left foot in T02. The assisted hip was contralateral to the perturbed foot: T01 recorded the indexed trajectory on channel 3 (left hip) and T02 on channel 0 (right hip). The HANK was operated with the powered knee orthosis control software, adapted to communicate with its motor drivers. Each trial contains two parts with separate elapsed clocks.
The logs include knee-angle estimates, warning states, indexed position setpoints, measured position, controller output, and motor and interaction torque channels. Positions are in degrees and torques in N·m. The controller output is a dimensionless PWM command. The four parts have effective export rates of 55.35–55.56 Hz and contain 40 warning starts. C5 had no pull-onset sensor.
Files and metadata
The ZIP contains Dataset/C1/ through Dataset/C5/ and Dataset/metadata/. C1 and C2 use MATLAB MAT v5 files. C3 uses tab-delimited controller text logs. C4 and C5 use MATLAB v7.3 files in which a single file can contain several indexed tables.
The nine metadata files are:
campaigns.csv summarizes the protocol, export rates, formats, and signal coverage by campaign.
participants.csv lists campaign-specific pseudonyms, the pseudonymous person_id shared by records from the same individual, and indexed recording counts.
trials.csv identifies the source file, internal table, participant record, trial, part, stream, and available protocol labels.
events.csv gives event types, timing references, zero-based source sample indices, and timestamps in seconds.
recording_layout.csv gives source and retained row counts, durations, and layout identifiers.
file_schema.json documents fields, storage types, and known units.
sensors.json describes signal tiers, time fields, and units.
c1_auxiliary_quality.csv reports finite-value coverage and constant values for the C1 auxiliary fields.
c1_auxiliary_gaps.csv lists missing intervals in those fields by source sample index and elapsed time.
How to use the data
1. Extract the ZIP and retain the Dataset/ directory structure. Open Dataset/metadata/trials.csv.
2. Resolve source_path relative to Dataset/. Where source_table is populated, select the indicated table using MATLAB or a compatible reader.
3. Join the recording, event, and layout indexes using recording_id. Use event_type, reference, and timing_reference to identify the temporal anchor for your analysis.
4. Apply any analysis_end_s cutoff and use each recording part's own clock. Preserve the original event reference when resampling or combining signals. Empty metadata fields indicate unavailable or inapplicable values.
5. For participant-independent evaluation, keep all records with the same person_id on the same side of the train/test split.
Validation and suitable uses
The accompanying data descriptor documents archive coverage, timestamp checks, perturbation annotation, paired sensor agreement, actuator tracking, and participant-held-out benchmarks. For C4, the comparison of Xsens and controller knee-angle estimates retained 1,079 twenty-second windows across 47 paired parts. On the 60 Hz analysis grid, the median window root-mean-square difference was 4.02° and the median Pearson correlation was 0.992. In C5, the median tracking error between commanded and measured hip position was 5.36° for the left hip and 6.23° for the right hip.
Participant-held-out logistic baselines using knee angle achieved 21.9% sensitivity in C1 and 11.7% in C2 for continuous onset detection. In a separate C1 task with the annotated onset supplied, the classifier distinguished intended heel-strike and toe-off targets with 94.6% balanced accuracy using a window from −250 to +250 ms. Using strictly pre-onset samples from those same 556 events gave 89.5%. In unperturbed walking, classification of kinematically estimated heel strikes and toe-offs gave 99.2% balanced accuracy using pre-event knee-angle samples.
SlipAssist supports comparisons with matched unperturbed walking in C1, perturbation detection benchmarks in C1 and C2, and comparisons of paired knee-angle estimates in C4. The C3 and C5 recordings support descriptive analysis of controller behaviour and actuator tracking in two single-participant cases. Cross-campaign analyses should account for differences in protocol, sensors, and event definitions.
Access and citation
The Zenodo record lists the Creative Commons Attribution 4.0 International (CC BY 4.0) license. File access is restricted during peer review, with editor and reviewer access arranged through the journal submission system. Public file access is planned after acceptance of the accompanying descriptor, subject to confirmation of the scope of consent and approvals. When reusing the dataset, cite the DOI of the version you accessed and the accompanying data descriptor.
Files
Additional details
Related works
- Has part
- Thesis: https://hdl.handle.net/1822/79823 (Other)
- Journal article: 10.3389/frobt.2024.1367474 (DOI)