Published November 23, 2026 | Version 1.0

Null-Calibrated Horizon-Durability Testing of an ECG-Based Prognostic Biomarker: Pre-Registrations, At-Standard Run Outputs, and Verification Script — Evidence Package for a Validation-Methods Chapter

Authors/Creators

  • 1. Fidelity National Information Services, Inc., Jacksonville, Florida, USA

Description

This package deposits the complete evidence base for the chapter proposal "Null-Calibrated Horizon-Durability Testing: A Pre-Registered Validation Protocol for AI-Based Prognostic Biomarkers", submitted to the edited volume Artificial Intelligence in Clinical Biomarkers and Organ-Specific Diagnostics (eds. Sah & Gaur, IGI Global; call 10430; proposal due December 13, 2026). Every empirical number cited in that proposal and in the chapter outline recomputes from the files here, using the included verification script (verify_deposit_numbers.py, 34 checks).

The chapter specifies a pre-registered, null-calibrated protocol that tests whether a prognostic score's incremental value over a demographics-only baseline genuinely attenuates across prediction horizons, or whether the apparent fade is manufactured by the evaluation itself (censoring weights, shrinking risk sets), by comparing observed horizon slopes against a constant-effect null at a replicate standard of R ≥ 200 (R = 1,000 as run).

On the public CODE-15% cohort (233,182 patients; 8,272 deaths; test split 69,955), the at-standard run returned concordant / no split under the frozen verdict rule: the incremental concordance slope (−0.00108/yr) sat at the 2.1st percentile of its null but failed the pre-registered opposite-sign condition, and the incremental accuracy slope (−0.00086/yr) sat at the 0.0th percentile. The motivating split verdict did not reproduce; the recorded reading is CLOSE for the implemented experiment. Six implementation limitations bound that reading (point-horizon rather than integrated accuracy scores; horizon rather than conditional-landmark evaluation; a test-split diagnostic refit; T2-only Cox fitting; a 6.79M-parameter network; a network net-benefit arm) and are stated in full in the verdict document. Paired net-benefit analysis shows no consistent or material advantage for the full model; clinical materiality is explicitly not established. The pre-registered rule permits no re-run.

Files

paper09_chapter_evidence_v1.zip

Files (46.8 kB)

Name Size
md5:695d2dcbe9f64b1864ba7a6dfafa77ba
46.8 kB Preview Download

Additional details

Related works

Is derived from
Dataset: https://zenodo.org/records/4916206 (URL)