There is a newer version of the record available.

Published November 20, 2026 | Version v0.3.31

Hertzon: an open-source electromagnetic design suite

Authors/Creators

Description

Added

  • Far field over an infinite ground plane. A far-field surface that is open at one flat outer face of the model (PML or radiation boundary on the other five sides, the floor a conductor, e.g. a monopole on a ground) is mirrored at that face (image theory), and the far field behind it is zero. Before, the image was missing and the pattern was that of the open surface alone. Symmetry planes and the PML far-field box of Auto Open work as before.
  • Post-processing for AI assistants. New tools evaluate_fields (Fields Calculator values on the saved fields: Poynting flux through any sheet, face, cut plane or the closed boundary of a solid, volume and surface integrals, maxima, point values) and get_power_budget (per port: accepted, reflected, transmitted, radiated and lost power, the balance, and the volume losses per object and material split into dielectric/conduction and magnetic). The Fields Calculator knows the magnetic loss tangent tandm; add_material takes tan_delta_m.
  • AI assistants can lay out a board and pick where analyses run. New MCP tool board: the board of a circuit as the 2D board editor shows it (parts, routes with length, width, impedance and insertion phase, connections not yet routed), and its actions Auto Place, moving parts, Connect (lines of one impedance with tapers and bends), Match Phase (equal phase or a set phase offset per route, with meanders) and the bend of a route. New MCP tool cloud: where the analyses of a window run, the server types of the cloud provider with cores, memory and price per hour, a choice of target per window, and deleting the window's server. With own_server a window gets a cloud server of its own, so the parts of a larger design, each in its own project and window, are solved in parallel on several servers.
  • Claude plugin skills for system design: split a system (for example a VNA test set) into parts, design them separately, assemble them on the board with Connect and Match Phase, and estimate time and cost serially and in parallel on cloud servers; every unconverged solve is reported to the user.
  • MCP tool report_issue. When a tool is missing (a structure the Design Wizard does not have), fails or gives a result that looks wrong, the assistant prepares an issue for the Hertzon developers: title, what happened, an example, a proposal and the versions of Hertzon, EMerge and the system, with a link to the prefilled "New issue" page of the repository. Nothing is sent; the user reads the text and posts it from the link.
  • Port mode labels. Every mode of a wave port is named after its type, the mode of a rectangular guide it resembles and its propagation constant, for example "P1 M2 (TE10-like, beta 72.3 rad/m)"; a mode that resembles none gives its symmetry instead ("TE, odd in x"). The field plot dialog lists the excitations of the solution with these labels (before it offered 1 ... number of ports, so the second mode of port 1 appeared as "2" and the modes of the last ports could not be chosen), the plot title and Edit Sources show them.
  • Setup: Delta S of complex S or of |S|. "Delta S of" (Convergence) chooses whether the passes converge on the change of the complex S-parameters (default, as before) or of their magnitudes only.
  • MCP: port modes. get_results(kind="ports") lists the modes of every wave port with label, type, beta, alpha, Zo, propagating or not, the symmetry about the two principal axes of the port face (even = magnetic wall, odd = electric wall) and the closest rectangular guide mode, plus the excitations whose fields are stored; image=true adds a picture of the transverse E of every mode. set_field_plot takes port and mode.

Changed

  • Real connectors: where the trace ends is stated. Putting a connector at a lumped port now says how far the trace is cut back from the board edge in Full 3D (the footprint length J1_lf; the contact then rests on the pad only) and that in Ideal the trace still runs to the edge under the connector, which the Transition model de-embeds. The help of the modes says the same.
  • Single Points sweeps take ';' or ',' between the frequencies (2.4GHz;2.45GHz or 2.4GHz,2.45GHz). The schema help of the sweep's Points was the one of polyline points.
  • Unknown choice values are refused. A sweep distribution such as "SinglePoints" fell back silently to Linear Step 1-10 GHz; the solver now stops with the valid names, and the AI tools refuse an unknown value of any choice property (any upper or lower case is accepted).
  • "Touch tangentially" is information, not a warning, in the Validation Check and the solver log, and coaxial cylinders of the same radius (a coax whose dielectric is the outer cylinder minus the pin) are no longer reported.
  • Cloud server shared by all windows. Closing a Hertzon window no longer deletes the cloud server that other windows (also of other Hertzon processes) use: each window holds a lease, and the server is deleted when the last window that uses it closes. If analyses still run or wait there, Hertzon asks first (delete, keep until idle, or cancel).
  • A lost cloud server is reported, never replaced silently. An analysis whose server disappears ends as "aborted because the cloud server was lost" with the reason (another window, Delete Cloud Servers, the server's watchdog, which now announces why it deletes a busy server, or outside Hertzon) instead of exit -999999; optionally it is queued again on a new server. cloud/events.log in the work folder records what happened to each server.
  • Costs of the cloud server in the status bar: price per hour from the provider's API and the costs so far; Check Account lists running time and costs of every server.
  • Secrets in the key store of the operating system. API tokens, secret keys and the token of a paired remote computer are kept in Windows Credential Manager, the macOS Keychain or the Secret Service of Linux (new dependency keyring), no longer in the registry or settings file; existing values are moved at the next start.
  • Analyses on this computer say so when a cloud is set up but switched off, and warn before they start when their last run needed more memory than is free.

Fixed

  • The memory guard of the adaptive meshing stopped a pass too early on small machines. Since it plans with the memory this analysis can use (its own plus the free memory, so other programs and analyses are counted), the old 10 % reserve on top was twice the margin: the hairpin filter on a 16 GB machine stopped a pass before 0.3.30 did, although that pass fitted (forecast 13.9 GB, peak 12.0 GB). The guard now plans with 95 % of the usable memory; the hairpin solves as in 0.3.30 again (same mesh and S-parameters).
  • Real connectors, mode Transition: S21 had the wrong sign. The line port of the transition design had no voltage line, and its mode came out with the opposite polarity to the coax mode, so the transmission phase through a connector was off by 180 degrees (with connectors at both ends of a board the two errors cancelled). The line port now has a voltage line from the ground to the trace and mode type TEM (the polarity of the dispersive microstrip mode is then also aligned at the top of the band). Measured on a 20 mm microstrip with a 2.92 mm connector, 1–20 GHz: the cascade against Full 3D from max |ΔS21| 1.99 to 0.038, same mesh, time and memory. Existing transition designs are marked stale; set the mode again and solve them once.
  • Wave ports with several modes: Delta S no longer jumps on a sign flip of a mode. Between adaptive passes the sign of every port mode was matched on the S-parameters of port 1 only. A mode that does not couple to port 1 (the second mode of a symmetric guide, an odd slot mode) was flipped on numerical noise, and Delta S jumped to about 2 with every |S| and phase unchanged (a two-mode guide: pass 6 Delta S 1.99 instead of 0.02), so the complex Delta S could not be used and the passes ran on. Now the modes of every pass are sampled at fixed points of the port face and matched to the modes of the previous pass by their field overlap (order and sign), and the sign of a mode is otherwise fixed on its strongest couplings, not on noise. A change of the mode order between passes is reported in the Message Manager.

Windows installer (Hertzon-Setup-*.exe) and Linux package (Hertzon-*-linux.tar.gz).

The FEM solver core of Hertzon is EMerge, the open-source FEM solver by Robert Fennis.

Notes

If you use Hertzon in your work, please cite it as below, and also cite EMerge, its FEM solver core.

Files

c8501024/Hertzon-v0.3.31.zip

Files (34.6 MB)

Name Size
md5:5f3e0ab95f9b2005dd5055194d339aae
34.6 MB Preview Download

Additional details

Related works

Software