Published November 18, 2026 | Version v1

Data and code for "How the capacity test biases the state of health of second-life EV batteries: evidence from retired LiFePO₄ cells"

  • 1. ROR icon Multimedia University

Description

Capacity-test data for twelve retired CALB LiFePO₄ prismatic cells (72 Ah rated; nine in the analysis set, SOH 60.6–74.9%), each tested under five capacity-test protocols in one chained Arbin schedule: a reference CC-CV charge to C/20 with 0.2 C discharge (run first and last), no constant-voltage stage, constant voltage to C/50, and a 0.25 C discharge. Includes per-run results (capacity, energy, efficiencies, internal resistance, CV duration), full voltage/current time series of the nine analysis cells, the Arbin schedules, and Python scripts that regenerate every table and figure of the associated paper. Tests were run at 22–23 °C at Multimedia University, Cyberjaya, Malaysia, in September–October 2026.

Files

protocol_bias_dataset_v1.0.zip

Files (7.1 MB)

Name Size
md5:027952742f4f250ab9da0aa30eae6e36