Silent Failure in Self-Assessed Perception: Health Signals Are Blind, External Anchors Are Cheap
Description
Analysis scripts and result files for the paper "Silent Failure in Self-Assessed Perception: Health Signals Are Blind, External Anchors Are Cheap".
The package lets every number reported in the paper be checked. It does not let those numbers be recomputed from scratch: the roughly 210 MB of per-frame disparity caches from which the result files are derived are not included, and are available from the author on request, as are the reference depth and the degraded re-renders.
Part A - SUPPLEMENT.zip (Secs. 5, 6 and 8)
Three analysis scripts and every per-condition result file they emit:
- metric_vs_truth.py evaluates health signals against the reference
- audit_probe.py evaluates ground-truth-free audit signals
- external_reference.py simulates anchor sparsity
- metrics*.json, m_*.json, probe_*.json and external_reference.json are the result files behind Tables II, III and V and behind Fig. 3
- RESULTS.md is the analysis log
- CASES.md is the working record from which the eighteen incidents in Table I were transcribed
- README.md maps each file to the table or figure it produces
Part B - SUPPLEMENT_S7.zip (Sec. 7)
Four measurements from modules of the same deployment other than depth. Each module exposes its own health quantity:
- dense_odometry.py - registration: fitness 0.98-1.00 and inlier RMSE 3.3-4.2 cm on 449/449 frames, yet a 170.03 m trajectory for a 15 s capture; 7.07 m once colour is added
- check_pose_freeze.py - ego-motion: 916 of 1800 frames bit-identical to their predecessor (50.9%), longest unbroken run 717 frames
- snap_planes.py and merge_planes.py - multi-view consistency: one wall reproduced as eight parallel planes spread over 35 cm
- locate_blur.py - surface thickness: 4.4 mm falling to 3.0 mm as frames grow from 150 to 1800, while the map stops being a room
- README.md records what each script produced, verbatim, and what is not included
In every case the reported number is well-formed, stays maximal or improves where the output degrades, and describes a property the module itself controls rather than the property the consumer needs. The four failures do not share a single cause.
The measurements in Part B come from separate instrumentation of the same system and were taken at different times from those in Part A; they are archived alongside rather than merged with them for that reason.
Environment: Python 3 with numpy, open3d and opencv-python. check_pose_freeze.py needs only numpy.