EGS Collab Experiment 2 (SURF, South Dakota): distributed temperature sensing in the four grouted monitoring boreholes (Geothermal Data Repository 1428), standardized (Open Well Data)
Authors/Creators
Description
Distributed temperature sensing in the four grouted monitoring boreholes of EGS Collab Experiment 2 at SURF: about 48 million depth-time readings from Geothermal Data Repository submission 1428.
The four temperature-corrected NetCDF files (AML_DTS_corrected.nc, AMU_DTS_corrected.nc, DML_DTS_corrected.nc, DMU_DTS_corrected.nc) mapped to the Open Well Data 1.5.0 monitoring schema: one row per value of the two 2-D arrays (down_data and up_data: rows = positions along the fibre, columns = times), 48,291,054 rows. Order: borehole, then downgoing and upgoing section, then time, then position. source_row is the row of the array (from 1) and quality_flag names the array and its column (time index, from 1). Values in degC as published (the files say "degrees C"); they are the authors' data corrected for the calibration bath bias (report, section 4.4), which the report recommends using. md = the depth coordinate of the file (m, distance along the fibre from the collar of the borehole, where the fibre enters and leaves it, mapped by heating, report section 4.2). Upgoing section: in AML, AMU and DML the rows of up_data run from the toe to the collar (the opposite order of the depth coordinate), so their md is the depth coordinate in reverse order; in DMU up_data is already in the order of the depth coordinate. Evidence: the mean temperature profile of up_data, reversed (or not, in DMU), matches that of down_data to 0.01-0.04 degC, against 2.0-2.9 degC the other way round.
Known issues: The md of the upgoing section comes from the order of the rows (see above); the best match of the mean profiles is with a shift of one position (0.25 m) in AML, DML and DMU, and the Joule-Thomson anomalies of report table 1 appear about 0.25 m shallower in the upgoing rows than in the downgoing rows (also in AMU), so up to about 0.25 m of uncertainty in the md of the upgoing rows, and the two sections do not sample exactly the same points.
48,291,054 rows in 1 data table(s), plus a well_links table.
Attribution: Rodriguez Tribaldos, V., Johnson, T., Robertson, M., Schwering, P., Ajo-Franklin, J., Burghardt, J., & St Clair, J. (2022). EGS Collab Experiment 2: Distributed Fiber Optic Temperature Data (DTS) [Data set]. Geothermal Data Repository. Lawrence Berkeley National Laboratory. doi:10.15121/1971114 (CC BY 4.0). Changes: see README.
The standardized copy is released under CC BY-NC 4.0; the original data remain under Creative Commons Attribution 4.0 International (CC BY 4.0). Credit the provider as well as this record. Commercial use of the copy requires written permission from the author (contact@openwelldata.org). Values are given as reported by the source, without warranty, and the source has not endorsed this copy.
Questions and corrections: contact@openwelldata.org.
Notes
Files
gdr-egs-collab-dts.zip
Additional details
Related works
- Is derived from
- 10.15121/1971114 (DOI)
- Is part of
- Dataset: 10.5281/zenodo.23961755 (DOI)