Published November 14, 2026 | Version v1

IceTop Shower Size and Energy: The S125 Budget at the South Pole

Description

This paper computes a shower-development budget for the IceTop surface array of the IceCube Neutrino Observatory at the South Pole, using published observations as inputs and standard relations stated in full. The principal computed quantities are: S125 VEM 1, energy proton eV 2e+15, energy iron eV 3.4e+15; S125 VEM 10, energy proton eV 2.244e+16, energy iron eV 3.56e+16; S125 VEM 100, energy proton eV 2.518e+17, energy iron eV 3.728e+17; snow correction factor = 1.331; energy proton at S125 10 eV = 2.244e+16; iron proton energy ratio at 10 = 1.587. Each value is derived in the deposited code from the stated inputs, so the budget can be re-run with alternative published values. The results place this measurement quantitatively alongside other observatories and energy ranges treated with the same relations, and the discussion identifies which input dominates the uncertainty of each headline number. Computed from stated assumptions and published data, not a new measurement.

Files

paper.md

Files (35.0 kB)

Name Size
md5:917b8d9773cf675f2d07d3e1627ca660
913 Bytes Download
md5:27b1212dd166f0ef91c5037bfff86a7b
17.2 kB Preview Download
md5:1989264c07eeac3a05bd1add7c675da9
16.2 kB Preview Download
md5:e8f1805ec2437d5f937b205b0468da4a
677 Bytes Preview Download