Published November 12, 2026 | Version v1

Potential Drop per Step in a Stepped Leader: Step Length, Pause Time and the Electric Field at the Advancing Tip

Description

This paper computes, from stated assumptions, a budget that is usually quoted without its arithmetic. The headline results from the deposited calculation are: dV = 3.00e+06, beta = 50.0, nsteps = 100, descent_ms = 25.0, Eamb = 6.0e+04. Before a cloud-to-ground flash connects, a stepped leader feels its way downward in short luminous jumps separated by brief pauses. The calculation is algebraic, every input is named in the Methods, and the deposited code reproduces every quoted number. A comparison with the neutron-branch density bound of the underlying frame is carried through and returns a negative result in plain terms: local densities in this problem are tens of orders of magnitude below that bound, so the bound changes no number reported here. The study is simulated and computed, not measured, and its conclusions are confined to the representative event described in the Methods.

Files

paper.md

Files (33.7 kB)

Name Size
md5:8515ad47532cee2a7c2557348bd58afc
1.5 kB Download
md5:c0b32cf7a8f462b336bff7c142cb7732
16.3 kB Preview Download
md5:00bc5473a37d1100dca9c431a0757065
15.2 kB Preview Download
md5:3f49c0e29ee44cce3f726653031936a6
700 Bytes Preview Download