Published November 10, 2026 | Version 1.0-review

Reproducibility Kit for LLM-Based Assessment of Chest Radiograph Report Quality

Authors/Creators

Description

This kit accompanies a paper under review that evaluates open-weight large language models (LLMs) as assessors of the structural quality of chest radiograph reports. Each report is checked against five binary criteria, one per anatomical region: bones, lung parenchyma, costophrenic angles, cardiothoracic ratio, and mediastinum. The kit covers two studies.

Study 1 is a survey of 17 radiology professionals about their trust in AI for image interpretation. The kit includes the questionnaire (in English), the de-identified responses, and the scripts for the correlation and Kruskal–Wallis tests.

Study 2 compares 45 configurations: eight open-weight LLMs (0.6B to 14B parameters), each run with and without 4-bit NF4 quantization, under zero-shot, few-shot, and chain-of-thought prompting. The kit includes the prompts, the evaluation notebooks, the results for every configuration and for the validation run, confusion matrices, summary figures, and the script for the inter-rater agreement analysis.

The dataset contains 227 anonymised chest radiograph reports from a public university hospital, each labelled on the five criteria and given an overall score from 0 to 5.

The README explains the file layout and how to run each analysis.

Files

kit.zip

Files (1.6 MB)

Name Size
md5:54f562735cc40d713ef8514e673624ff
1.6 MB Preview Download