Effect of Electrolyte Concentration on the Mass of Zinc Electrodeposited onto Iron from Acidified Zinc Sulfate Solutions
Authors/Creators
Description
The dependence of cathodic zinc deposition on electrolyte concentration was investigated for acidified zinc sulfate solutions (ZnSO₄·7H₂O, 0.1–0.5 mol dm⁻³, with 10 cm³ concentrated H₂SO₄ per 500 cm³) using zinc anodes and iron-nail cathodes under constant nominal electrical settings and a fixed deposition time. Deposited mass was determined gravimetrically (balance resolution ±0.001 g; propagated uncertainty ±0.002 g). Mass deposited increased monotonically from 0.010 g at 0.1 mol dm⁻³ to 0.068 g at 0.5 mol dm⁻³. A least-squares fit gave a slope of 0.144 ± 0.006 g per mol dm⁻³, an intercept of −0.006 ± 0.002 g and R² = 0.995 (n = 5, one trial per concentration), indicating a strong, approximately linear positive association over the range studied. Because cell current was not reported, the charge passed cannot be calculated, and a direct concentration effect cannot be distinguished from indirect effects arising through solution conductivity (and hence current) or cathodic current efficiency. Limitations and the measurements needed to resolve this are discussed.
Files
Effect of Electrolyte Concentration on the Mass of Zinc Electrodeposited onto Iron.pdf
Additional details
References
- 1. Biswal, H. J. "Investigations on the Effect of Electrode Gap Variation Over Pulse-electrodeposition Profile." IOP Conf. Ser.: Mater. Sci. Eng. 653, 012046 (2019). doi:10.1088/1757-899X/653/1/012046.
- 1. "Effect of ZnSO₄·7H₂O Concentration of Electrolyte Solution on Zn Electrodeposition Process." IOSR Journal of Applied Chemistry 14(9), 10–15 (Sept. 2021). Accessed 11 Sept. 2024.