Published November 5, 2026 | Version v1

High-speed laser Doppler holography of the eyelid, facial skin and anterior segment of the eye of a volunteer, revealing blood flow responses in subcutaneous vessels.

Authors/Creators

  • 1. ROR icon Centre National de la Recherche Scientifique

Description

High-speed laser Doppler holography of the eyelid, facial skin, and anterior segment of the eye in a volunteer

This dataset illustrates contactless imaging of blood-flow-sensitive signals in the eyelid and surrounding facial skin using high-speed laser Doppler holography (LDH). Recordings include closed- and open-eye states, revealing branching vascular structures beneath the eyelid skin and in the periocular region. The observations demonstrate how an ocular holography platform can visualize superficial vascular networks outside the pupil, including during eye closure.

LDH records interference between light scattered by tissue and a coherent reference beam. Numerical reconstruction provides access to the complex optical field, whose temporal fluctuations carry information about moving scatterers, including blood cells. Principal-component analysis (PCA) provides temporal demodulation and enables visualization of vascular contrast against the surrounding tissue background.

Acquisition used diffuse laser illumination of 10 mW distributed over approximately 5 × 5 cm². Holograms were recorded at 16,000 frames per second, with a 58 µs exposure time and a 62 µs frame period. Images were reconstructed by Fresnel propagation at a numerical distance of 508 mm. Processing used 32-frame PCA windows, with settings involving 8 (red channel) or 28 (cyan channel) of the lowest singular components, followed by accumulation of eight rendered images. For consecutive, nonoverlapping windows, this corresponds to a nominal output rate of 31.25 images per second. Camera acquisition rate, processed-image cadence, and exported-video playback rate are distinct.

The images provide qualitative, flow-sensitive optical contrast. They do not establish absolute blood velocity, volumetric flow, oxygenation, or anatomical vessel depth. Numerical refocusing does not provide depth-resolved vascular localization, and tissue motion and scattering can contribute to the measured signal. The data support exploration of periocular vascular imaging and the influence of reconstruction and temporal filtering on vessel visibility. Potential future applications include investigating vascular dynamics during eyelid reconstruction, skin-graft and flap healing, local anesthetic administration, and inflammatory eyelid conditions such as ocular rosacea, blepharitis, and meibomian gland dysfunction. 

Holographic reconstruction and visualization software: Holovibes.

Files

261102_FIY0713_8.mp4

Files (25.8 GB)

Name Size
md5:54423f059514ec9eaf2dd35269927cde
21.4 MB Download
md5:230bb42bf40ace6c19e2b1c8aea7dc36
25.8 GB Download
md5:d6da16eb44deaa0b510b3fea27875f88
6.9 MB Preview Download
md5:db9299d6eae2bcc04af9edde75577eb1
3.6 kB Preview Download
md5:d3e454117fd108a548865f8b74571580
3.6 kB Preview Download

Additional details

Software