Published October 22, 2026 | Version 1.0

FRALEX-TDP-017: A Repair That Has Stopped Leaking Has Not Yet Been Accepted

Authors/Creators

  • 1. FRALEX-ESS

Description

Technical Decision Paper on acceptance as the third decision point of a live intervention. It separates work complete, verified and accepted, sets criteria before the work, discusses what leak tests can and cannot resolve using the scope of leak-testing standards, and introduces grades of acceptance evidence V0 to V4, an observation period and a handover record. The paper is a decision-support framework, not a design specification, procedure or authorisation to work, and contains no design values. 

Further information on this topic and the related FRALEX documents: Acceptance of repairs – https://fralex-ess.eu/en/research/tdp-017-acceptance/

Files

FRALEX_TDP-017_Acceptance.pdf

Files (791.4 kB)

Name Size
md5:8b5017686fac51f1772158df7923caea
791.4 kB Preview Download

Additional details

Related works

Continues
Report: 10.5281/zenodo.23561584 (DOI)
Is described by
Other: https://fralex-ess.eu/en/research/tdp-017-acceptance/ (URL)
Is supplement to
Report: 10.5281/zenodo.23302531 (DOI)