First comparison of thermodynamic temperature realizations between 4 K and 303 K using capsule thermometers as transfer standards
-
Gaiser, Christof1
-
Bojkovski, Jovan2
-
CABALLERO, RAÚL3
-
Dobre, Miruna4
-
Gao, B.5
-
Imbraguglio, Dario6
-
Kırbaş, Cafer7
-
Kowal, Aleksandra8
-
Lopardo, Giuseppina6
-
Machin, Graham9
-
Martin, Catherine10
- Martin, M. J.3
-
Makofsky, David11
-
Nikonkov, Ruslan8
- Pant, U.10
-
Pitre, Laurent12
- Rinolfi, Simone6
-
RISEGARI, LARA13
-
Rourke, Patrick14
- Santoro, Federico6
-
Sparasci, Fernando13
- Song, Y.5
-
Steur, Peter P.M.6
-
Szklarz, Grzegorz8
- Tomazini, Zan2
-
Underwood, Robin James9
-
Veltcheva, Radka9
-
Voldán, Michal15
- Yang, Inseok16
-
Zhang, Haiyang17
-
Gavioso, Roberto Maria6
-
1.
Physikalisch-Technische Bundesanstalt
- 2. University of Ljubljana (UL), Slovenia
- 3. Centro Español de Metrología (CEM), Madrid, Spain
- 4. Federal Public Service Economy
- 5. State Key Laboratory of Cryogenic Science and Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences (TIPC-CAS), Beijing, PR China
- 6. Istituto Nazionale di Ricerca Metrologica (INRIM), Torino, Italy
- 7. Ulusal Metroloji Enstitüsü (TÜBİTAK), Gebze, Kocaeli, Türkiye
- 8. Institute of Low Temperature and Structure Research (INTiBS), Wrocław, Poland
- 9. National Physical Laboratory (NPL), Teddington, UK
- 10. Laboratoire National de Métrologie et d'Essais-Conservatoire National des Arts et Métiers (LNE-CNAM), La Plaine-Saint Denis, France
- 11. Czech Metrology Institute (CMI), Prague, Czech Republic
- 12. LNE-CNAM
- 13. LNE-Cnam
- 14. Metrology Research Centre, National Research Council Canada (NRC), Ottawa, Canada
- 15. Czech Metrology Institute
- 16. Korea Research Institute of Standards and Science (KRISS), Daejeon, Korea
- 17. Technical Institute of Physics and Chemistry, Chinese Academy of Sciences
Description
As a test of the potential dissemination of the kelvin by thermodynamic means, we have compared the thermodynamic calibration of 25 capsule thermometers by three primary gas thermometry methods over the range between 4 K and the melting point of gallium (MPGa) at 303 K. Thermodynamic realizations of the kelvin were obtained by seven laboratories, namely by dielectric-constant gas thermometry (DCGT) at PTB, by refractive index gas thermometry (RIGT) at TIPC-CAS, and by acoustic gas thermometry (AGT) at INRiM, KRISS, LNE-CNAM, NPL and NRC. Final comparison activities were conducted by two laboratories, namely at INTiBS, for a subset of 15 thermometers of different kinds (Pt, PtCo, RhFe), using comparison blocks embedded in two different cryostats at several temperatures in the range between 5 K and the triple point of xenon (TPXe) at 161 K, and at UL, for 10 capsule-type standard platinum resistance thermometers (cSPRTs), by the realization of the fixed points which define the International Temperature Scale of 1990 (ITS-90) between the triple point of argon (TPAr) and the melting point of gallium (MPGa), including the triple point of mercury (TPHg) and the triple point of water (TPW) at 273.16 K. Over the whole investigated range, no inconsistency was found between the thermodynamic calibrations of different laboratories. The claimed standard uncertainties of these calibrations, between 0.07 mK and 1.4 mK, compare favourably with those of current ITS-90 realizations. The resolution of this first comparison was ultimately set by the transfer process, namely the stability of the capsule thermometers over multiple inter-laboratory transfers and thermal cycles, and the reproducibility with which several capsules can be brought to a common reference temperature. The experience gained defines the conditions for a follow-up comparison with a finer resolution.
Files
Comparison of T between 4 K and 303 K.pdf
Additional details
Funding
- European Association of National Metrology Institutes
- European Partnership on Metrology 100019599