Beyond 99%: Auditing Leakage, Shortcuts and Calibration in COVID-19 CT Classification
Authors/Creators
Description
A 99.76%-accuracy COVID-19 CT classifier turns out to measure much less than it claims. I audited it end to end and wrote it up as a preprint (v1.0, October 12 2026).
Key findings :
• Showed that slice-level splits inflate accuracy by placing near-duplicate slices in both train and test: recovered pseudo-
paGent groups by clustering deep and thumbnail features, and measured accuracy falling from 99.42% to 95.39% under
grouped splits (error up to 8.0x).
• IdenGfied shortcut learning: a metadata-only model reached 0.996 balanced accuracy on random splits (0.630 under
grouped splits), and the classifier kept ~0.93 balanced accuracy with the lungs masked out, confirmed with Grad-CAM
lung-enrichment analysis.
• Tested external validity and calibraGon on Sao Paulo and Tehran (COVID-CT-MD) data: AUROC ≈0.83 externally, near
chance (0.43-0.49) for COVID vs community-acquired pneumonia, and calibraGon error rising from 0.02 to 0.19-0.53;
released a one-script reproducible pipeline and a 7-step audit protocol.
Files
beyond99percenttest1.pdf
Additional details
Dates
- Issued
-
2026-10-12Audit of a 99.76%-accuracy COVID-19 CT classifier: slice-level leakage, shortcut learning, external validation (Sao Paulo, Tehran) and calibration under shift. PyTorch, reproducible from one script.
Software
- Repository URL
- https://github.com/PopcornKitsilano/covid-ct-audit
- Programming language
- Python , Jupyter Notebook
- Development Status
- Active