How Often Does Stereo Visual Odometry Fail, and Can It Be Predicted? Natural Flights, Controlled Degradation and Transfer of a Monocular Predictor
Description
Monocular visual odometry (VO) loses tracking under aggressive rotation, and earlier work in this series built a telemetry-based predictor for that failure. Stereo VO has a metric baseline and may behave differently. We recorded 50 simulated flights (35,455 stereo frame pairs) and found that a classical stereo VO pipeline almost never fails: 130 frames (0.37%) are failures, 98 of them in the last stretch of a single flight. Because that is too few events to test early warning, we ran a pre-registered injection campaign of 140 further flights (99,148 frames) under seven conditions. On held-out flights, a logistic model ranks frames that precede a degradation within five frames with AUROC 0.915, but tracker health signals alone do as well, image-quality features add nothing, and the gain over copying the current state is small (+0.03). Skill is uneven: warnings cover 96% of low-light onsets but none of the frame-drop onsets, and AUROC falls to 0.84 without low light. A model trained on gradual degradations reaches 0.80 on unseen mechanisms. The monocular predictor from our earlier work, applied unchanged to six stereo flights, raised alarms on 41% of frames in proportion to yaw rate. The evidence is limited to one simulator, one baseline and one VO implementation.