iohsample: sampling-interval and reconstruction-rule bias in intraoperative hypotension burden (A-1.7.1)
Description
iiohsample is the Python package used for the analysis in "Sampling interval and reconstruction rule alter measured intraoperative hypotension burden in non-cardiac surgery: a resampling analysis of 3411 cases" (manuscript submitted for publication). It resamples continuous invasive arterial pressure from the VitalDB open dataset onto regular 1-5 min grids, an irregular clinical regime and thinned references, reconstructs the area under a mean arterial pressure threshold with three rules (exact linear interpolation, clipped trapezoidal rule, zero-order hold), and computes bias, agreement and classification statistics.
This record contains release A-1.7.1 exactly as tagged in the source repository (commit 14259b501c0ec4ae22edbe1c00da7882dc17dce5). The commit identifier is stored as the comment of the ZIP file. The release passes its full test suite (151 tests). All analytical constants are held in iohsample/config.yaml.
Derived results, configuration files and a script that reproduces the canonical parameter digest of the primary analysis are archived in a separate Zenodo record. Some documentation files in this release are in Turkish; English documentation is provided in the derived-data record.
Requirements: Python 3.12 with numpy, pandas, polars, pyarrow, scipy, vitaldb and PyYAML (exact versions are listed in the Supplementary Material of the article).
Files
iohsample-modulA-1.7.1.zip
Additional details
Software
- Programming language
- Python