FRALEX-TDP-006: A Clamp Is a Load Path Not a Cover
Description
A bolted clamp that has stopped a leak has proved its seal, not its load path. This white paper sets out what a mechanical enclosure must demonstrate before it is accepted as a repair: damage mapped beyond the visible leak, a defined path for every load including pressure thrust, a fit to the surveyed geometry, compatible seals and bolting, a proved tightness, and a classification as repair or temporary repair with an end date and an inspection plan. It applies the FRALEX Decision Architecture and its three-point Decision Gate (selection, execution release, acceptance), includes an illustrative worked example and decision record, and states when a clamp is not the right answer. It is a decision-support framework, not a design specification.
Files
FRALEX_TDP-006_Mechanical_Enclosures.pdf
Files
(489.8 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:e752cf0923d84f62f837bd17b7370cd3
|
489.8 kB | Preview Download |
Additional details
Related works
- Is described by
- Other: https://fralex-ess.eu/research/tdp-006-mechanical-enclosures/ (URL)
- Is supplement to
- Publication: 10.5281/zenodo.22900736 (DOI)