Corrosion Effects on the Long-Term Durability and Performance of Activated Fe-SMA for Structural Strengthening
Authors/Creators
Description
The use of iron-based shape memory alloys (Fe-SMAs) for active retrofitting applications has increased in recent decades due to their potential cost-effectiveness and shape memory effect, which enables the generation of prestressing forces without the need for bulky conventional prestressing devices. However, their long-term behavior, particularly under environmental exposure, is not yet fully understood. This study investigates the durability of activated Fe-SMA in a corrosive environment. Activated specimens are subjected to accelerated corrosion in a chloride solution to simulate long-term material deterioration. Special attention is given to the evolution of mechanical properties that are critical for the design of strengthening systems. Results show that under normal conditions, Fe-SMA can experience stress relaxation of up to 15% in the first 400 hours, after which the recovery stress stabilizes. However, when exposed to corrosive conditions, recovery stress loss continues over time, exceeding 25% relaxation. Corrosion also leads to a reduction in ultimate tensile strength and strain capacity. This study also examines the possibility of reactivation of Fe-SMA after cyclic loading. Without any additional thermal stimulation or corrosion after the initial activation, Fe-SMA can be reactivated following loading cycles, reaching similar values as the initial activation. However, with corrosion, recovery stress is reduced in each subsequent reactivation. These findings provide insight into the long-term degradation mechanisms of activated Fe-SMA under environmental exposure and their implications for structural performance. The results also support the introduction of design considerations to account for recovery stress reduction and mechanical property degradation in long-term service conditions.
Files
12_Corrosion Effects on the Long-Term Durability and Performance of Activated Fe-SMA for Structural Strengthening.pdf
Additional details
References
- ASTM International. (2014). 'ASTM D638–14: Standard test method for tensile properties of plastics'. West Conshohocken, PA: ASTM International.
- ASTM International. (2016). 'ASTM E8/E8M–16a: Standard test methods for tension testing of metallic materials'. West Conshohocken, PA: ASTM International.
- ASTM International. (1999). 'ASTM G44-99: Standard practice for exposure of metals and alloys by alternate immersion in neutral 3.5% sodium chloride solution'. West Conshohocken, PA: ASTM International.
- Cladera A., Oller E., and Ribas C. (2014a). 'Pilot experiences in the application of shape memory alloys in structural concrete', Journal of Materials in Civil Engineering, vol. 26 (no. 11), pp. 04014084-1–04014084-10, https://doi: 10.1061/(ASCE)MT.1943-5533.0000974.
- Cladera A., Weber B., Leinenbach C., Czaderski C., Shahverdi M., and Motavalli M. (2014b). 'Iron-based shape memory alloys for civil engineering structures: An overview', Construction and Building Materials, vol. 63, pp. 281–293, https://doi: 10.1016/j.conbuildmat.2014.04.032.
- Czaderski C., Shahverdi M., Brönnimann R., Leinenbach C., and Motavalli M. (2014). 'Feasibility of iron-based shape memory alloy strips for prestressed strengthening of concrete structures', Construction and Building Materials, vol. 56, pp. 94–105, https://doi: 10.1016/j.conbuildmat.2014.01.069.
- Dong Z. , Liu Z. , Ji J. , Zhu H. , Wu G. , and Sun C. (2023). 'Characterization of self‑prestressing iron‑based shape memory alloy bars for new structures, Construction and Building Materials', vol. 371, p. 130795, https://doi: 10.1016/j.conbuildmat.2023.130795.
- Hong K., Lee S., Han S., and Yeon Y. (2018). 'Evaluation of Fe-based shape memory alloy (Fe-SMA) as strengthening material for reinforced concrete structures', Applied Sciences, vol. 8 (no. 5), pp. 730, https://doi: 10.3390/app8050730.
- Kulkarni P. V. , Oza M. J. , Igual‑Muñoz A., Sallese J. M. , Shahverdi M., Leinenbach C. , and Mischler J. (2025). 'Corrosion behavior of heat‑treated Fe‑based shape memory alloys', Materials and Corrosion – Werkstoffe und Korrosion, vol. 76 (no. 1), pp. 10–19, https://doi: 10.1002/maco.202414562.
- Lee W. J., Partovi-Nia R., Suter T., and Leinenbach C. (2016). 'Electrochemical characterization and corrosion behavior of an Fe-Mn-Si shape memory alloy in simulated concrete pore solutions', Materials and Corrosion – Werkstoffe und Korrosion, vol. 67 (no. 7), pp. 839–846, https://doi:10.1002/maco.201508701.
- Liu Z. , Dong Z. , Zhu H. , Gu W. , and Wen Y. (2023). 'Stress recovery behaviour of a large‑diameter Fe‑SMA stranded wire developed for structural prestressing loss compensation', Advances in Structural Engineering, vol. 26 (no. 5), pp. 966–982, https://doi: 10.1177/13694332221149475.
- Maji B. C. , Das C. M., Krishnan M. , and Ray R. K. (2006). 'The corrosion behaviour of Fe‑15Mn‑7Si‑9Cr‑5Ni shape memory alloy', Corrosion Science, vol. 48 (no. 4), pp. 937–949, https://doi: 10.1016/j.corsci.2005.02.024.
- Shahverdi M., Czaderski C., Michels J., and Motavalli M. (2018). 'Iron-based shape memory alloy strips for strengthening RC members: Material behaviour and characterization', Construction and Building Materials, vol. 173, pp. 586–599, https://doi: 10.1016/j.conbuildmat.2018.04.057.
- Sun X. , Dong Z. , Zou C. , Zhu H. , Sun Y. , and Pan Y. (2024). 'Hinge joint performance in hollow‑core slab bridges transversely strengthened with local near‑surface mounted iron‑based shape memory alloy (Fe‑SMA) bars', Construction and Building Materials, vol. 455, p. 139181, https://doi: 10.1016/j.conbuildmat.2024.139181.