Published September 12, 2026 | Version v1

COMPARATIVE EXPERIMENTAL EVALUATION OF TRADITIONAL AND IMPROVED NOISE MEASUREMENT METHODS IN A SMALL INDUSTRIAL ZONE

Description

The paper presents a comparative experimental evaluation of the traditional 
(continuous stationary) and the improved (time-distributed) methods of noise level 
measurement in a small industrial zone. The study was carried out in the Yakkasaray small 
industrial zone of Tashkent on a regular 50-metre measurement grid, with both methods 
applied in parallel at identical points. The mean difference between the methods amounted 
to 1.26 dB for the A-weighted equivalent level and 1.04 dB for the C-weighted level, 
remaining within the technical accuracy limit of ±1.5 dB specified by IEC 61672. The 
improved method increased the efficiency of noise source detection within a 50-metre radius 
by 63.6 per cent and reduced labour costs twentyfold. On this basis the method is 
recommended for acoustic monitoring practice.

Files

Nasiba S.pdf

Files (754.8 kB)

Name Size Download all
md5:e59d1d4912de32005538da7c656ba416
754.8 kB Preview Download