[SUPERSEDED] Centrepost Fluence, Damage, and the Consumable-Cartridge Life of a Spherical-Tokamak Breeder
Description
This record has been superseded. The current, updated version is The Centrepost Life-Limiter: Fast-Fluence, dpa, and Shielding Setting the Cartridge-Replacement Cadence for a Compact Spherical-Tokamak Breeder (DOI 10.5281/zenodo.22645708). Please read and cite the current version. This page stays online so existing citations keep resolving.
Centrepost fast-neutron fluence, displacement damage, and consumable-cartridge life of a compact spherical-tokamak breeder from coupled OpenMC neutronics. The damage rate and cartridge-replacement interval are booked against a tungsten-carbide shield whose thickness trades directly against machine size and breeding coverage; the mid-current point extends the life. The centrepost is handled as a scheduled-replacement cartridge, not a lifetime component. Physics and engineering only.