A Kohlrausch or Weibull Exponent Below One Admits a Classical Mixture: Pollard's Criterion as a Licence Condition, Two Predictions Refutable Against Existing Literature, and a Self-Audit of the Framework That Produced Them
Authors/Creators
Description
Consolidated edition. This version merges the three previous papers of the programme into a single document, reordered by logical dependency rather than chronology so that the surviving core is separable from the speculation built on it. 63 pages, 26 sections in 7 parts, 8 appendices.
Eloy René Becerra Daly
What is established, in decreasing order of confidence
- [EXACT] Identities. The Λ-hierarchy reduces to τ = ℏ/E and ℓ = the reduced Compton wavelength. The accessible information satisfies IQ = (γ/τ)β exactly. A distinguished point at D/L = 1/2 carries four coincident properties — exactly one bit, the entanglement sudden-death point for C0 = 1, the maximum of D·C̄ at L²/4, and a Bures arc of π/3 — all invariant in β, τ and L.
- [OBS] Verification. D + C = 1 holds to machine precision across 650 circuits on two IBM backends and ~5.5×106 shots.
- [THM] Limits. A no-go theorem shows the temporal exponent of dephasing is independent of the pulse-sequence filter, which removes the derivation previously claimed for Axiom 3 and relabels it as an empirical postulate.
- [THM] The transferable result. Pollard's criterion used as a licence condition: β ≤ 1 certifies that the curve admits a positive rate density, β > 1 proves that none exists. In reliability engineering an infant-mortality exponent licenses reading the batch as heterogeneous, while a wear-out exponent forbids it under any partition. Six transfers are registered, each with the observation that would retire it.
The inference this work does not license
A fitted β < 1 is not evidence of quantum behaviour. The theorem establishes representability of the curve, not identification of the mechanism — the map from mechanism to curve is many-to-one — so what follows is weaker and sufficient: the data cannot be adduced as evidence of coherence, because a classical account of them exists.
The decisive test, which is not performed here
On a single sample, the anomalous-diffusion exponent and the stretched-relaxation exponent must satisfy β = (1 + αdiff)/2, with β ≥ 1/2 as a corollary. Both quantities are already tabulated in the NMR relaxometry and diffusion-imaging literature for overlapping sample sets. No new experiment is required to attempt this refutation.
Errata to previous versions
The critical qubit number is n* = 1.848, not 2.6. The LIGO ringdown significance, with the internal error scaled by √(χ²/ν) = 1.669 as the catalogue's own goodness of fit requires, is 12.5σ; we record that our first correction of it, 20.9σ, was itself wrong for neglecting that scaling, and that the originally published 13.8σ was closer to the defensible value than our correction. A reported 18 kHz emergence mode lies below the Rayleigh limit of its own data. The published comoving density of remnants corresponds to Ω = 0.063, not the 0.12 it is stated to reproduce.
Endpoint, labelled CONJ throughout
The programme closes with a dark-matter candidate: Planck-scale black-hole remnants at Mmin = mP/(2√π) = 6.140 µg, an exact identity rather than the approximation 0.28 mP under which it was published. Evaluating it shows the usual dismissal to be right for the wrong reason: the remnant carries 148.6 J at galactic velocity and one transit is expected per 0.86 km²·yr, so rarity is not the obstacle; but the mean free path in rock is 1023 light years and the probability of one interaction while crossing the Earth is 10-32. The candidate is cross-section-limited, not exposure-limited, and the two demand opposite experiments. Four falsifiers are given, two requiring no new instrument.
Reproducibility
Every numerical claim is recomputed from the equations by a dependency-free implementation: 354 regression tests and 37 published-number checks, over a registry of 138 equations each carrying source, evidence level and declared domain. Where a published number could not be reproduced it is recorded as an erratum rather than adjusted; where a correction of ours proved wrong it is recorded as such. The register documents 27 inconsistencies, of which 11 remain open, each with the observation that would close it.
Notes
Files
elb8-dev/sdf-decoherence-paper-v2.0.0.zip
Additional details
Software
- Repository URL
- https://github.com/elb8-dev/sdf-decoherence-paper