Time-zero biopsy and deceased-donor kidney transplant outcomes: data and code
Authors/Creators
- 1. Hospital Civil de Oriente, Tonalá, Jalisco, Mexico
- 2. Centro Estatal de Trasplantes de Jalisco (CETRAJAL), Guadalajara, Jalisco, Mexico; Centro Médico Puerta de Hierro Norte, Zapopan, Jalisco, Mexico
- 3. Hospital Juárez de México, Mexico City, Mexico
- 4. Hospital General de México Dr. Eduardo Liceaga, Mexico City, Mexico
- 5. Hospital Civil de Oriente, Tonalá, Jalisco, Mexico; Centro Universitario de Ciencias de la Salud (CUCS), Universidad de Guadalajara, Guadalajara, Jalisco, Mexico
- 6. Hospital Regional de Alta Especialidad del ISSSTE, Acapulco, Guerrero, Mexico
- 7. Centro Médico Nacional 20 de Noviembre, ISSSTE, Mexico City, Mexico
- 8. Centro Universitario de Tlajomulco, Universidad de Guadalajara, Tlajomulco, Jalisco, Mexico; Hospital Civil de Oriente, Tonalá, Jalisco, Mexico
- 9. Hospital Civil de Oriente, Tonalá, Jalisco, Mexico; Centro Universitario de Tlajomulco, Universidad de Guadalajara, Tlajomulco, Jalisco, Mexico
Description
This deposit supersedes an earlier one. An earlier deposit (DOI 10.5281/zenodo.21224579, July 2026) reports an analysis that has since been replaced. Do not use it. This is a separate record, not a new version of it.
Data, analysis ledgers and code supporting the systematic review and meta-analysis Time-zero kidney biopsy and deceased-donor transplant outcomes. Registration: PROSPERO CRD420261435405. Reporting: PRISMA 2020. Searches: five bibliographic databases and three trial registries, inception to 25 July 2026, no date or language restriction.
The superseded deposit reported 152 reports collapsed to 118 cohorts and a vascular / delayed-graft-function odds ratio of 1.996 (95% CI 1.578-2.525), k = 10, I² = 0%. This deposit reports 225 reports representing 159 study investigations and 154 cohort families, and the same association as OR 1.85 (95% CI 1.11-3.06), k = 7, I² = 68.4%. The earlier I² = 0% in particular should not be cited: heterogeneity is substantial.
Contents: data/ every extracted estimate through to the analysis-ready input; results/ every model fitted, including 216 prespecified sensitivity and 65 leave-one-out analyses; certainty/ GRADE profiles, summary of findings, limitations and risk of bias; code/ the analysis specification, the model code and its environment. FILE_INDEX.csv describes every file; MANIFEST_SHA256.txt verifies the whole deposit.
No human-subject data. Published study-level results only. Raw licensed database exports and copyrighted full texts are not redistributed.
Files
FILE_INDEX.csv
Files
(1.7 MB)
| Name | Size | |
|---|---|---|
|
md5:ef1fd92040d58a9f4bb30efdb926b4d3
|
3.4 kB | Download |
|
md5:8e204ce0372b64c750c4ecec13e169c1
|
8.3 kB | Preview Download |
|
md5:c874a6aa29781e21902d96ad93a6b429
|
1.9 kB | Preview Download |
|
md5:e73094ef827137d4882f101a8f669994
|
4.9 kB | Preview Download |
|
md5:59dd92915aadbb700e1e3571bf173708
|
5.1 kB | Preview Download |
|
md5:cd0e5a3bde2f9d289556671598a1155e
|
1.6 MB | Preview Download |
Additional details
Related works
- Is new version of
- 10.5281/zenodo.21224579 (DOI)
- Is supplement to
- https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=420261435405 (URL)