Published July 28, 2026 | Version v1

Dataset of paper "Photocatalytic façades in open urban environments: A CFD assessment of surface removal and volumetric air-purification effectiveness"

Authors/Creators

Description

Dataset of paper "Photocatalytic façades in open urban environments: A CFD assessment of surface removal and volumetric air-purification effectiveness"

  • Histogram showing the distribution of  values on the building walls for the selected mesh used in the CFD simulations.
  • Histogram showing the distribution of  values on the building walls for the mesh with   used for comparison in the CFD simulations.
  • Vertical wind velocity profiles at different distances from the inlet for the studied wind velocity conditions.
  • Vertical NO concentration profiles at different distances from the inlet for the studied wind velocity conditions.
  • Percentage of NO removed by photocatalysis calculated using the concentration-based method at different control volumes. The results include the total relative removal and the differential contribution of each control volume region.
  • Molar concentration of NO removed by photocatalysis calculated using the concentration-based method at different control volumes. 
  • NO (ppb) removed across the width of the central corridor for two mesh densities (y⁺ ≈ 1 and y⁺ ≈ 100) at the beginning and end of the corridor.
  • Percentage of NO removed by photocatalysis calculated using the concentration-based method for two mesh resolutions (y⁺ ≈ 1 and y⁺ ≈ 100).
  • NO removal rate by photocatalysis calculated using the molar flux for two mesh resolutions (y⁺ ≈ 1 and y⁺ ≈ 100).
  • Vertical wind velocity profiles at different distances from the inlet for the studied wind velocity conditions with the barrier.
  • Vertical NO profiles at 150 m from the inlet for the studied wind velocity conditions with the barrier and without. Vertical NO profile at 5 m from façade for the studied wind velocity conditions with the barrier
  • Ppb of NO after and before the photocatalytic treatment on the façade of the building. 
  • Ppb of NO2 and NO3 after the photocatalytic treatment on the façade of the building with and without barrier. 
  • NO (ppb) removed across the width of the central corridor for two mesh densities (y⁺ ≈ 1 and y⁺ ≈ 100) at the beginning and end of the corridor.
  • Percentage of NO removed by photocatalysis calculated using the concentration-based method at different control volumes for the barrier’s case. The results include the total relative removal and the differential contribution of each control volume region.
  • NO removal rate based on molar flux different control volumes for barrier’s cases. 
  • NO (ppb) removed across the width of the central corridor for two mesh densities (y⁺ ≈ 1 and y⁺ ≈ 100) at the beginning and end of the corridor for a wind speed of 5 m s-1.
  • Percentage of NO removed by photocatalysis calculated using the concentration-based method for two mesh resolutions (y⁺ ≈ 1 and y⁺ ≈ 100) for a wind speed of 5 m s-1.
  • NO removal rate by photocatalysis calculated using the molar flux for two mesh resolutions (y⁺ ≈ 1 and y⁺ ≈ 100) for a wind speed of 5 m s-1.

Files

DICTAMINA_URJC_Paper3_01_1.0.0.zip

Files (474.1 kB)

Name Size
md5:44c3a198a6b567913b0687d33f54d9ca