Published July 20, 2026 | Version v1

The tube transducer as a novel source for power ultrasound: A case study in delamination of graphite coating from lithium-ion battery anode

  • 1. James Watt School of Engineering, University of Glasgow
  • 2. ROR icon University of Glasgow
  • 3. ROR icon University of Leicester

Description

This publication presents a novel tube transducer for power ultrasound applications and evaluates its performance in the delamination of graphite coatings from lithium-ion battery anodes. The study compares the technology with a conventional sonotrode and highlights its potential for more efficient, high-throughput, flow-based material recovery processes. This research was supported by the EU-funded APOLLO project and aligns with its mission of advancing circular technologies and innovative material recovery.

Files

The tube transducer as a novel source for power ultrasound.pdf

Files (28.4 MB)

Additional details

Funding

European Commission
APOLLO - A Proactive Approach to the Recovery and Recycling of Photovoltaic Modules 101122277