PLLA-TAP - DSC cooling curves at 5K-min
Authors/Creators
Description
PLLA-TAP – DSC cooling curves at 5K-min
1.1.Materials
A commercial PLLA grade, Luminy® L-130, with l-isomer content ≥ 99% and melt-flow index of 23 g/10 min (210 °C/2.16 kg), was kindly provided by TotalEnergies Corbion (The Netherlands). Triallyl phosphate (TAP) was purchased from TCI America as GC-grade with purity of 96%. Dicumyl peroxide (P) was purchased from Sigma-Aldrich with a purity of 98%, acetone from Romil as HPLC grade solvent.
1.2. Synthesis of long-chain branched PLLA
Operators: Aniello Staiano, Valentina Marturano, IPCB-CNR.
Before processing, PLLA pellets were dried overnight under vacuum at 60°C. Preparation of branched PLLA began with a pre-batch, by mixing dicumyl peroxide, triallyl phosphate and dried PLLA pellets in acetone, in order to promote adsorption of the reagents on the pellets surface. After complete evaporation of acetone, the pre-preg polymer pellets were further dried in at 60 °C under vacuum to remove traces of residual acetone, and of humidity.
Reactive mixing was carried out using a Brabender Plastograph EC (Brabender GmBH & Co.KG, Germany), at 180°C and mixing rate of 100 rpm for 6 minutes. Plain PLLA pellets were also processed using the same protocol.
Seven formulations were prepared, by fixing peroxide content at 0.2 wt%, while varying TAP from 0.1 to 1 wt%, as detailed in Table 1, which also presents sample codes.
Table 1. Sample codes and compositions
|
Sample code |
PLLA (g) |
P (g) |
TAP (g) |
|
PLLA |
100 |
0 |
0 |
|
TAP01 |
100 |
0.2 |
0.1 |
|
TAP02 |
100 |
0.2 |
0.2 |
|
TAP04 |
100 |
0.2 |
0.4 |
|
TAP06 |
100 |
0.2 |
0.6 |
|
TAP08 |
100 |
0.2 |
0.8 |
|
TAP1 |
100 |
0.2 |
1 |
1.3.Thermal analysis
Operator: Aniello Staiano, IPCB-CNR.
Thermal properties were investigated using a TA Instrument Q2000 Tzero DSC equipped with a RCS cooling accessory. Temperature and energy calibration were performed using a high-purity indium standard. The polymers were melted at 200 °C for 2 min, cooled at 170°C with a rate of 30 K min-1, to limit thermal degradation, then cooled to room temperature at 5 K min-1. Dry nitrogen was continuously fluxed as purge gas at a rate of 30 mL min-1.
The data report the heat flow rate plots (exo up) as function of temperature.