Published July 9, 2026 | Version v1

PLLA-TAP - DSC cooling curves at 5K-min

Description

PLLA-TAP – DSC cooling curves at 5K-min

 

1.1.Materials

A commercial PLLA grade, Luminy® L-130, with l-isomer content ≥ 99% and melt-flow index of 23 g/10 min (210 °C/2.16 kg), was kindly provided by TotalEnergies Corbion (The Netherlands). Triallyl phosphate (TAP) was purchased from TCI America as GC-grade with purity of 96%. Dicumyl peroxide (P) was purchased from Sigma-Aldrich with a purity of 98%, acetone from Romil as HPLC grade solvent.

 

1.2. Synthesis of long-chain branched PLLA

Operators: Aniello Staiano, Valentina Marturano, IPCB-CNR.

Before processing, PLLA pellets were dried overnight under vacuum at 60°C. Preparation of branched PLLA began with a pre-batch, by mixing dicumyl peroxide, triallyl phosphate and dried PLLA pellets in acetone, in order to promote adsorption of the reagents on the pellets surface. After complete evaporation of acetone, the pre-preg polymer pellets were further dried in at 60 °C under vacuum to remove traces of residual acetone, and of humidity.

Reactive mixing was carried out using a Brabender Plastograph EC (Brabender GmBH & Co.KG, Germany), at 180°C and mixing rate of 100 rpm for 6 minutes. Plain PLLA pellets were also processed using the same protocol.

Seven formulations were prepared, by fixing peroxide content at 0.2 wt%, while varying TAP from 0.1 to 1 wt%, as detailed in Table 1, which also presents sample codes.

 

Table 1. Sample codes and compositions

Sample code

PLLA (g)

P (g)

TAP (g)

PLLA

100

0

0

TAP01

100

0.2

0.1

TAP02

100

0.2

0.2

TAP04

100

0.2

0.4

TAP06

100

0.2

0.6

TAP08

100

0.2

0.8

TAP1

100

0.2

1

 

 

1.3.Thermal analysis

Operator: Aniello Staiano, IPCB-CNR.

Thermal properties were investigated using a TA Instrument Q2000 Tzero DSC equipped with a RCS cooling accessory. Temperature and energy calibration were performed using a high-purity indium standard. The polymers were melted at 200 °C for 2 min, cooled at 170°C with a rate of 30 K min-1, to limit thermal degradation, then cooled to room temperature at 5 K min-1.  Dry nitrogen was continuously fluxed as purge gas at a rate of 30 mL min-1.

The data report the heat flow rate plots (exo up) as function of temperature.

Files

PLLA-TAP - DSC cooling curves at 5K-min.txt

Files (715.3 kB)

Name Size
md5:c3283ac5ec9ee0e7b44c7b834dde4b20
715.3 kB Preview Download

Additional details

Funding

European Commission
BORN - BiObased theRmal-resistaNt food packaging 101223095