Published June 23, 2026
| Version v1
Dataset
Open
Cyclic voltammograms obtained at the 35-nm radius gold nanoelectrode in 0.5 M H2SO4 solution deoxygenated under argon
Authors/Creators
Description
Cyclic voltammograms (CVs) obtained at the 35-nm radius gold nanoelectrode in 0.5 M H2SO4 solution deoxygenated under argon at different scan rates (from 0.3 to 1 V/s). The potential range is 0-1.75 V vs RHE.
The data in the text files is given in the following format:
Potential vs. RHE (V) | Current (A)
Scan rate is indicated in the text file name.
The figure Voltammograms.tif shows all CVs in this dataset.
Files
Voltammograms.tif
Files
(1.6 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:68bad53f84b04d78d564b1309e012aea
|
408 Bytes | Preview Download |
|
md5:ccf170d9c0db2b9cf1d865343ed59c7d
|
169.7 kB | Preview Download |
|
md5:36e64a370d296d74034d03954cdd6130
|
167.7 kB | Preview Download |
|
md5:6fb6e529f7ed872f8c8051e63e752502
|
167.1 kB | Preview Download |
|
md5:022fe0978a4eb58b50669ad5ff194aa0
|
166.2 kB | Preview Download |
|
md5:b1877690afb9cf7560c06a5ca2b7faa4
|
165.7 kB | Preview Download |
|
md5:75f2e59c6ecc1fe652ad8751dd9190f6
|
166.2 kB | Preview Download |
|
md5:9561e82b73d771677679edbb7c4492ea
|
166.3 kB | Preview Download |
|
md5:0e8e3678d2aea799692e124a74acae87
|
165.7 kB | Preview Download |
|
md5:fa906b7d1f148a85abe9925a0b570e82
|
216.0 kB | Preview Download |