-تقييم الاداء الزلزالي للمباني البيتونية المسلحة القائمة بعد اضافة طوابق إضافية - حالة دراسية

  • 1. arab international university

Description

 

   In the recent years, Syria has witnessed a great renaissance in the construction sector and investment in it, accompanied by modifications in the construction control and allowing an increase in the number of floors of existing buildings. These additions are not taking into account the sufficient additional capacity to withstand vertical loads without noticing the accompanying structural damages caused by side loads such as possible earthquakes. Their occurrence during the life of the structure, which causes various damages as a result of the change in the seismic behavior of the elements of these buildings.                               This research deals with the study of the effect of adding floors to existing buildings without evaluating their efficiency on seismic loads, by studying two existing reinforced concrete buildings, one of them is a regular building and the other is irregular, horizontally and vertically, as they represent the most common model for existing facilities in Syria.       

        A seismic study was carried out using linear static and dynamic seismic analysis methods using the ETABS program, and the resulting responses were compared (floor shear forces, period, floor transitions, relative floor displacements). Then the performance and behavior of the buildings were evaluated after adding two and three floors under the influence of seismic loads by conducting anonlinear static analysis.                                 

     One of the most important findings of the research is that the two studied models  were  approached the level of life safety after adding two and three floors at high rates, and considering that the elements in the two models became unrealized, especially the columns, these additions are considered unrealized performance for designed shakes (design demand

 spectrum).                                                                                                        

         Therefore, the study recommends not adding floors to existing buildings except after conducting a comprehensive study of the buildings’ response to vertical and horizontal forces and verifying their performance after these additions to achieve the level of life safety for design demand spectrum and the level of collapse prevention for major tremors

this version is archived in the Arab International University(AIU) repository for open access and dissemination purposes .

The content of this paper has not been modified from the original publication .

for more information please visit the official repository of Arab International University (AIU)

https://www.aiu.edu.sy

Files

م.جنان ابوعاصي .pdf

Files (7.0 MB)

Name Size Download all
md5:03186f4b219046af7626dfd6257d53ba
7.0 MB Preview Download

Additional details

Additional titles

Alternative title (English)
Evaluation of the seismic performance of reinforced concrete buildings after adding additional floors - case study-

Dates

Available
2021-11

References

  • . American concrete Institute : Building code requirements for structural concrete ACI-318.
  • . ASCE. (2013). Seismic evaluation and retrofit of existing buildings (ASCE/SEI 41-13) New York, N.Y. -
  • Federal Emergency Management Agency (FEMA), 2000, Prestandard and Commentary for the Rehabilitation of Buildings, FEMA-356.