Published April 12, 2026 | Version Same as engrXiv version

IMPLEMENTATION OF KARNEY–TIJSSELING–GUIDAOUI TRANSIENT ENERGY FRAMEWORKS IN THE NUMERICAL ANALYSIS AND DESIGN OF A BIFURCATED GRAVITY IMPULSE FLOW FORMER (GIF²): AN ENTHALPY‑BASED ENERGY ANALYSIS

  • 1. FLOW JET ENERGY LTD

Description

This work was originally published on engrXiv (DOI: https://doi.org/10.31224/6794).
This Zenodo record is provided as a mirror to consolidate the HSPP/GIF² research collection.

ABSTRACT

        Classical hydraulic engineering treats transient processes such as water hammer as parasitic phenomena that should be avoided [1–4]. In contrast, this work demonstrates that controlled hydraulic transients can be utilized for the temporary concentration and redistribution of energy within a hydraulic cycle [10]. We present a numerical energy analysis of the GIF² system—a novel hydraulic converter operating under a minimal gravitational head of 0.9 m. The system self-organizes into a bifurcated flow structure: the main supply branch generates discrete high-energy liquid modules (141.3 L, 120 atm), while the control branch dissipates small sacrificial modules (0.26 L, 3.3 kJ) that provide synchronization and hydraulic isolation.

        The analysis employs a local volumetric energy density ε(t) = (P − Patm) + ½ρv², evaluated at fixed spatial control points [1, 19]. This quantity represents the specific mechanical work of the flow (the enthalpy-related pressure contribution together with the kinetic component) per unit volume [22, 23]. The true elastic energy (fluid compression and pipe wall deformation) is evaluated separately and is small (< 0.8% of the integral work potential of the module).

Key results:

    • During formation, the module is kinematically isolated in volume but energetically open. Its state is characterized by the integral quantity Hmax = (P − Patm)V, which is interpreted not as stored energy but as the maximum pressure work that can be realized during the displacement process to atmospheric pressure.

    • After losses (reflections 18.6%, stabilizer 15.3%, control branch 0.2%), the energy delivered at the nozzle is Hdel = 1125.5 kJ, corresponding to a conversion efficiency η = Hdel/Hmax = 66.1%.

    • The high cyclic coefficient KEPcycle = Hdel / Egravity = 574 reflects not energy amplification, but its temporal concentration and redistribution within the cycle (accumulation over ~0.4 s and release over ~2 ms), as well as dynamic transformation described by the Joukowsky relation (2c/v ≈ 136).

    • An additional contribution is provided by internal energy recovery from the previous cycle (controlled rarefaction to p ≈ −0.8 atm), which represents energy redistribution within the system and provides approximately 38.5 kJ per cycle for pre-acceleration of the flow.

    • The system operates in an accumulative transient regime with a Karney φ-index of φ = 0.745 [11], and the observed KEP agrees with the scaling relation KEP ∝ (τacc/τdis)·φ/(1 − φ) with an error < 2%.

    All results are based on one-dimensional modeling using the method of characteristics with an effective wave speed c = 910 m/s, accounting for fluid–structure interaction and compliance due to the presence of gas [2, 9, 18]. The analysis is consistent with the law of energy conservation and with the classical theory of transient flows in pipelines.

Files

Manuscript v5.2 – 12.02.2026 En.pdf

Files (1.6 MB)

Name Size
md5:b5d48669e4193473e42fb5d0536bc675
1.6 MB Preview Download

Additional details

Related works

Is described by
Report: 10.5281/zenodo.19672920 (DOI)
Is supplement to
Preprint: 10.31224/6825 (DOI)
Preprint: 10.31224/6826 (DOI)
Preprint: 10.5281/zenodo.19672528 (DOI)

References

  • Article 2, Preprint: Materials science justification and service life of the GIF² system, DOI: 10.31224/6825
  • Article 3, Preprint: Engineering matching of the impulse source (GIF²) and the turbine terminal (RTM), DOI: 10.31224/6826
  • Article 4, Preprint: Sensitivity analysis and stability assessment of the GIF² system, DOI:10.5281/zenodo.19672528
  • Report: Feasibility Study (FS), DOI:10.5281/zenodo.19672920