The Safety and Efficacy of Anterior Chamber (AC) Maintainer in Manual Small Incision Cataract Surgery (MSICS) vs Ophthalmic Visco Surgical Devices (OVD) A Quasi Experimental Study in Tertiary Care Centre
Authors/Creators
- 1. International Journal of Medical Science and Advanced Clinical Research (IJMACR)
Description
Abstract
Introduction: Cataract remains the leading cause of blindness worldwide and manual small incision cataract surgery (MSICS) is the most widely adopted technique in developing countries, where phacoemulsification is not financially viable.
Aims and Objectives
Primary Objectives: To evaluate safety and efficacy of AC Maintainer in manual small incision cataract surgery, with reference to visual outcome.
Other Objectives: To study intraoperative complications, postoperative complications and outcomes.
Material and Method:
Study Design: Quasi Experimental study
Study Period: The study was conducted over a period of 18 months
Place of study: The study was conducted at Department of Ophthalmology at Tertiary Care Center.
Sample Size: Total sample size were 133 and randomly collection
Sampling Method: Complete Enumeration method
Result: Sample size is determined by Complete Enumeration method Minimum sample size were 133 and compared to preoperative values, Group I is VISCO group with N=30 and Group II is AC Maintainer also N=30.
Discussion: The current study, investigating a new type of anterior chamber maintainer (ACM) and to its reveal a higher incidence of intraoperative and early postoperative complications with its use compared to ocular viscosurgical devices (OVD).
Files
SIDDHESH.pdf
Files
(925.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:fd90d561325a652d306baf68cc13ba43
|
925.3 kB | Preview Download |
Additional details
Software
- Repository URL
- https://www.ijmacr.com/issue/archive_issue/69
References
- 1. Erdem Y, Huseyin BO, Mehmet OC. Balanced salt solution-assisted intraocular lens implantation in phacoemulsification surgery: intraocular pressure and endothelial cell effects. Beyoglu Eye J. 2019;4(1):05-10. 2. Sachin Daigavane, Prarthna Patkar .To Compare the changes in the corneal endothelium post phacoemulsification surgery with balanced salt solution vs. viscoelasticsdevice.Journal of clinical and diagnostic research. 2019 Dec vol-13(12); NC01-NC04 3. Vasileios Lakidis1, Antonios Lakidis2,3, Despoina Kolokotroni2, Diamantis Almaliotis2, Vasileios Karampatakis2 open journal of ophthalmology,2012,2,127-130 4. Guy Sallet Clinical Ophthalmology 2008:2(4) 717-721 5. The use of anterior chamber maintainer in special cataract cases.Open journal of Ophthalmology,2012, 2, 127-130. 6. Viscoless microincision cataract surgery.Clinical Ophthalmology 2008:2(4)717-721 7. Small Incision Manual Cataract Surgery Mini-Nuc and Fluidics Phacosection and Viscoexpression. Prof. Michael Blumenthal, M.D. Prof. Peter Kansas, M.D. 8. Changes in Corneal thickness and corneal endothelial cell density after phacoemulsification cataract surgery;aouble-blind randomized trial.April 2018, vol'10, issue;4,pages6616-6623. 9. Auffarth GU, Holzer MP, Vissesook N, et al. 2004a. Removal times and techniques of a viscoadaptive ophthalmic viscosurgical device. J Cataract Refract Surg, 30:879–83. 10. Auffarth GU, Holzer MP, Vissesook N, et al. 2004b. Removal times for a dispersive and a cohesive ophthalmic viscosurgical device correlated with intra-ocular lens material. J Cataract Refract Surg, 30:2410–14. 11. Blumenthal M, Assia EI, Chen V, et al. 1994. Using an anterior chamber maintainer to control intra-ocular pressure during phaco-emulsifi cation. J Cataract Refract Surg, 20:93–6. 12. Chang DF, Campbell JR. 2005. Intraoperative floppy iris syndrome associated with tamsulosin. J Cataract Refract Surg, 31:664–73. 13. Galan A. 2005. Phaco-emulsifi cation without the use of visco-elastic devices. Ocular Surgery News. Europe/Pacifi c Edition, April 2005. 14. Kiss B, Findl O, Menapce R, et al. 2003. Corneal endothelial cell protection with a dispersive viscoelastic material and an irrigating solution during phacoemulsifi cation : low-cost versus expensive combination. J Cataract Refract Surg, 29:733–40 15. Leaming DV. 2004. Practice styles and preferences of ASCRS members – 2003 Survey. J Cataract Refract Surg, 30:892–900 16. Milla E, Verges C, Cipres M. 2005. Corneal endothelium evaluation after phacoemulsifi cation with continuous anterior chamber infusion. Cornea, 24:278–82. 17. Moser CL, Martin-Baranera M, Garat M, et al. 2004. Corneal edema and intra-ocular pressure after cataract surgery: randomized comparison of Healon5 and Amvisc Plus. J Cataract Refract Surg, 30:2359–65. 18. Ota I, Myake S, Miyake K. 1996. Dislocation of the lens nucleus into the vitreous cavity after standard hydrodissection. Am J Ophthalmol, 121:706–8. 19. Rainer G, Menapace R, Findl O, et al. 2001. Intra-ocular pressure rise after small incision cataract surgery: a randomised intraindividual comparison of two dispersive viscoelastic agents. Br J Ophthalmol, 85:139–42. 20. Schipper I, Lechner A, Senn P. 2000. Intraocular pressure after phacoemulsifi cation and implantation of silicone haptic intraocular lenses without viscoelastics. Klin Monatsbl Augenheilkd 2000; 216: 96–98 21. Shingleton BJ, Mitrev PV. 2001. Anterior chamber maintainer versus viscoelastic material for intraocular lens implantation: case-control study. J Cataract Refract Surg, 27:711–14. 22. Yachimori R, Matsuura T, Hayashi K, Hayashi H. 2004. Increased intraocular pressure and corneal endothelial cell loss following phacoemulsification surgery. J Cataract Refract Surg, 35:453–9 23. Bissen-Miyajima H. Ophthalmic viscosurgical devices. Curr Opin Ophthalmol. 2008; 19:50-54 24. Tak H. Hydroimplantation: foldable intraocular lens implantation without an ophthalmic viscosurgical device. J Cataract Refract Surg. 2010; 36:377-379 25. Joussen MA, Barth U, Cubuk H, Hans-Reinhard K. Effect of irrigating solution and irrigating temperature on the cornea and pupil during phacoemulsification. J Cataract Refract Surg 2000;26:392-7. 26. Floyd M, Valentine J, Coombs J, Olson RJ. Effect of incisional friction and ophthalmic viscosurgical devices on the heat generation of ultrasound during cataract surgery. J Cataract Refract Surg 2006; 32:1222-6. 27. Tognetto D, Cecchini P, Ravalico G. Survey of ophthalmic viscosurgical devices. Curr Opin Ophthalmol 2004;15:29-32. 28. Lehmann R, Brint S, Stewart R, et al. Clinical comparison of Provisc and Healon in cataract surgery. J Cataract Refract Surg 1995;21:543-7