MRSI semiLASER pulse sequence for Bruker ParaVision 5.1
Authors/Creators
Contributors
Project leader:
Researcher:
Supervisor:
Description
Source code for MRSI semiLASER pulse sequence in Bruker ParaVision 5.1, instructions to compile and deploy the method, and test data sets.
The MRSI-semiLASER sequence was implemented in-house on a 7T Bruker Biospec system running ParaVision 5.1, and its performance was compared to the commercially available CSI-PRESS sequence. The results demonstrated that the MRSI-semiLASER sequence achieved improved spatial distribution homogeneity and up to a 1.2-fold increase in SNR compared to CSI-PRESS in murine brain tumors, allowing a 20% reduction in slice thickness without compromising spectral quality. These findings establish the implemented MRSI-semiLASER sequence as a robust tool for high-resolution MRSI acquisition in mouse brain studies, and it is now available for use by interested researchers.
Notes
Files
MRSI semiLASER pulse sequence for Bruker ParaVision 5.1 - Record Content.pdf
Files
(3.1 GB)
| Name | Size | |
|---|---|---|
|
md5:4422219281b9fbfb9c78636418fc157c
|
35.5 kB | Download |
|
md5:301250d9bb079c3a0f51b835fe14a7a0
|
50.5 kB | Preview Download |
|
md5:f776efa42f3da88761e6ea4717372f78
|
36.1 kB | Download |
|
md5:a5c3fb3bca66040b15c28d2c98e90ca9
|
64.7 kB | Preview Download |
|
md5:4ca4808d381cbac6f85f0b3a5be7576c
|
6.0 kB | Preview Download |
|
md5:bba1b84633a0c6af0a6232f463aee8a4
|
54.1 kB | Download |
|
md5:b743fe3abdc57c52881cbd44685f187a
|
122.3 kB | Preview Download |
|
md5:3406df8ca54ae4ce2804bcb108818156
|
588.8 MB | Preview Download |
|
md5:e979a7431ad9f58b7b501e18ae6b71ea
|
202.8 MB | Preview Download |
|
md5:5bbb44a197a1bf699d6a3a0d2518e7bb
|
202.8 MB | Preview Download |
|
md5:921b293512b5a5b77c0f7929e645ac48
|
202.7 MB | Preview Download |
|
md5:1f4ff6d0ab0062eefa0e05252574610d
|
1.4 GB | Preview Download |
|
md5:b8e305428243d32a6f1b0d77e40e3dc3
|
494.6 MB | Preview Download |
Additional details
Additional titles
- Subtitle
- Pulse sequence source code and test data sets
Funding
- European Commission
- INSPiRE-MED - INtegrating Magnetic Resonance SPectroscopy and Multimodal Imaging for Research and Education in MEDicine 813120
- Instituto de Salud Carlos III
- Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) Grant No. CB06/01/0010
- European Commission
- ATTRACT - breAkThrough innovaTion pRogrAmme for a pan-European Detection and Imaging eCosysTem 777222
- Agencia Estatal de Investigación
- Metabolomic Crossroads: Unraveling The Interplay Between Tumor Microenvironment And Metabolic Reprogramming. Impact In Glioma Therapy Response And MR-Based Follow-Up (TIMER-GLIO). MCIN/AEI/10.13039/501100011033. Grant No. ID2023-147750NB-I00
- Agència de Gestió d'Ajuts Universitaris i de Recerca
- XarTEC SALUT 2021 XARDI 00021