Description

This dataset is obtained in framework of WeBaSOOP Project. The uploaded .txt document is formatted according to the EBAS submision template. The uploaded .txt file contains metadata with the information regarding start time and end time of the measurements.

Originator: Jovasevic-Stojanovic, Milena; Jovanovic, Maja; Petrovic, Bojana
Affiliation: Vinča Institute of Nuclear Sciences, VINCA, Mike Petrovic Alasa 12-14, 11351, Belgrade, Serbia
Submitter: Petrovic, Bojana
Project: Horizon Europe project "Research Reinforcing in the Western Balkans in Offline and Online Monitoring and Source Identification of Atmospheric Particles" - WeBaSOOP, GA. 101060170, https://cordis.europa.eu/project/id/101060170

Time zone: UTC
Start date: 2023 03 01 23:00:00
Period code: 1 year
Resolution code: 4 days
Sample duration: 24 hours
Station name: Bor Gradski park
Station land use: Urban park
Station setting: Urban and center city
Station latitude: 44.076111
Station longitude: 22.099444
Station altitude: 378 m
Component: oxidative potential_AA assay
Unit: nmol/min/m3
Matrix: pm10
Laboratory - sampling: Mining and Metallurgy Institute Bor
Instrument type: low_vol_sampler
Instrument manufacturer: Mega System
Instrument model: Lifetek PMS
Laboratory - analysis: Vinča Institute of Nuclear Sciences
Analytical measurement technique: uv_absorption
Analytical instrument manufacturer: BioTek/Agilent
Analytical instrument model: Synergy H1 Microplate reader
Inlet type: Impactor--direct
Inlet description: Upward facing with rain shield
Flow rate: 38.3 l/min
Filter face velocity: 44.0 cm/s
Exposed filter area: 14.5 cm2
Filter description: PALLFLEX Tissuequartz 2500QAT-UP 47mm
Medium: Quartz
Filter conditioning: 293.15 K, 50.0 %RH, 48.0 h
Sample preparation: Water extraction
Blank correction: Blank corrected
Humidity/temperature control: None
Humidity/temperature control description: filter kept at ambient conditions together with sampling head
Volume std. temperature: ambient
Volume std. pressure: ambient
Detection limit expl.: LOD based on 3 x sd of fieldblanks
Zero/negative values code: Zero/negative impossible
Originator: Jovasevic-Stojanovic, Milena, mjovst@vin.bg.ac.rs