Published December 24, 2025 | Version v1
Publication Open

Rapid ElectroMagnetic Induction profiling for pre-drill risk reduction in water-well siting

  • 1. GEONUM
  • 2. ROR icon Université Grenoble Alpes

Description

Drilling a productive water well in heterogeneous hillside terrain often comes down to choosing the right spot within a few tens of meters. We describe a rapid electromagnetic induction (EMI) survey designed to guide such a decision. Using a CMD-DUO system at 925 Hz with three coil separations (10, 20, 40 m) and two orientations (HCP/VCP), we profiled ~100 m across an agricultural field above a perennial spring. Apparent conductivity increases systematically toward the western end of the transect, with the deepest configurations showing the strongest contrast. Inversion in EMagPy yields a laterally restricted conductive body at ~8–15 m depth (overall RMSPE < 5%). We interpret this anomaly as a plausible drilling target, consistent with perched saturation or wetter colluvium feeding the downslope discharge, while acknowledging that EMI alone cannot distinguish saturation from clay enrichment. The workflow illustrates how dense, multi-configuration EMI profiling and transparent inversion can reduce pre-drill uncertainty at low cost.

Files

Article_EM_MJT_FVD_23_12_2025_WEB.pdf

Files (962.2 kB)

Name Size Download all
md5:6acb5253be47d1242bfc2cc2a61dc709