Abstract

Introduction: This in-vitro study was undertaken to compare the dimensional accuracy of dies obtained by using different tray materials and pouring casts at different time intervals.

Objectives

1.      To compare the dimensional accuracy of dies obtained from auto polymerizing acrylic resin custom tray from the metal die model.

 2. To compare the dimensional accuracy of dies obtained from light cure acrylic resin custom tray from the metal die model.

3. To compare the dimensional accuracy of dies obtained from metal stock tray from the metal die model.

4. To compare the dimensional accuracy of dies obtained from plastic stock tray from the metal die model.

5. To compare dimensional accuracy of dies obtained from all tray materials poured at different time intervals that is at immediate pouring, 24 hours and 72 hours amongst each other.

Materials and Methods: Vinyl polysiloxane in putty and light body consistency were used for making impressions. A stainless steel die with specific dimensions was used for making the samples. Two indentations were made on the top and lateral side of the die. Total 12 groups were made using each type of tray at immediate, 24 hrs and 72 hrs time interval. 120 samples were fabricated ten per group. Three readings were recorded for each sample and average of the three were compared amongst themselves. Linear measurements were done using profile projector. Data was collected and analysed statistically.  

Results: Based on the study it can be concluded that dimensional accuracy was comparable at immediate pouring with different tray materials as the horizontal and vertical distance was found to be statistically non- significant. However, on comparison of horizontal and vertical distance at 24 hr and 72 hr it was found that result of dimensional accuracy was best for light cure tray followed by custom tray, stock metal tray and stock plastic tray.

Files

GARG.pdf

Files (1.2 MB)

Name Size
md5:e3c61e0e87012551adedbde899152fa9
1.2 MB Preview Download

Additional details

References

  • 1. S.Y. Chena, W.M. Liang, F.N. Chen. Factors Affecting The Accuracy Of Elastometric Impression Materials, Journal Of Dentistry (2004) 32, 603–609. 2. Nachum Samet, Michal Shohat, Alon Livny, And Ervin I. Weiss. A Clinical Evaluation of Fixed Partial Denture Impressions, J Prosthet Dent 2005;94:112-7. 3. Tavakolizadeh Sara, Razaghi Mohammad, Pakravan Pedram, Monfared S. Majid, Beyabanaki Elaheh. Effect Of Multiple Pouring On The Accuracy Of Casts Made Using 3D-Printed Custom Trays With Different Spacer Thicknesses: A Research Study. J. Dent Res Dent Clin Dent Prospect 2020; 14(1):37-40. 4. Ali Hafezeqoran, Mahdi Rahbar, Roodabeh Koodaryan And Tina Molaei. Comparing The Dimensional Accuracy Of Casts Obtained From Two Types Of Silicone Impression Materials In Different Impression Techniques And Frequent Times Of Cast Preparation, International Journal Of Dentistry, Volume 2021, Article ID 9977478. 5. P. A. De Araujo, And K. D. Jorgensen. Effect Of Material Bulk And Undercuts On The Accuracy Of Impression Materials, The Journal Of Prosthetic Dentistry, December 1985 Volume 54 Number 6, 791-94. 6. Tjan AHL, Whang SB: Comparing Effects Of Tray Treatment On Accuracy Of Dies. J Prosthet Dent 1987;58: 175-178. 7. Dheeraj Kumar, Anand U Madihalli, K Rajeev Kumar Reddy, Namrataa Rastogi, NT Pradeep. Elastomeric Impression Materials: A Comparison of Accuracy of Multiple Pours, J Contemp Dent Pract 2011;12(4):272-278. 8. Rafael Pino Vitti, Marcos Aurélio Bomfim da Silva, Rafael Leonardo Xediek Consani, Mário Alexandre Coelho Sinhoreti. Dimensional Accuracy of Stone Casts Made from SiliconeBased Impression Materials and Three Impression Techniques, Brazilian Dental Journal (2013) 24(5): 498-502. 9. Roland P. Pagniano, Rickne C. Scheid, Ronald L. Clowson, Richard 0. Dagefoerde and Lyle D. Zardiackas. Linear dimensional change of acrylic resins used in the - fabricatian of custom trays, The Journal of Prosthetic Dentistry, 1982;47(3);279-83. 10. M. Goldfogel, W. L. Harvey and D. Winter. Dimensional change of acrylic resin tray materials. The Journal of Prosthetic Dentistry 1985 Volume 54 Number 2,284-86. 11. Huey-Yuau Wang, Yo-Chin Lu, Yuh-Yuan Shiau, and Daniel Tsou, Vertical distortion in distal extension ridges and palatal area of casts made by different techniques. J PROSTHET DENT 1996;75;302-8. 12. T. J. Bomberg, R. A. Hatch, and W. Hoffman. Impression material thickness in stock and custom trays. The Journal of Prosthetic Dentistry, 1985 Volume 54 Number 2,170-72. 13. Varun Kumar, Himanshu Aeran. Evaluation of Effect of Tray Space on the Accuracy of Condensation Silicone, Addition Silicone and Polyether Impression Materials: An In Vitro Study, J Indian Prosthodont Soc (July-Sept 2012) 12(3):154–160. 14. A. M. Lacy, T. Bellman, H. Fukui, and Malcolm D. Jendresen. Time-dependent accuracy of elastomer impression materials. Part I: Condensation silicones, The Journal of Prosthetic Dentistry, 981 Volume 45 Number 2,209-15.