Published January 1, 2023 | Version v1

Data from "Optimal position of air purifiers in elevator cabins for the improvement of their ventilation effectiveness"

  • 1. ROR icon Universidad de Oviedo
  • 2. University of Oviedo
  • 1. University of Oviedo
  • 2. ROR icon Universidad de Oviedo

Description

Data Documentation for:
"Optimal position of air purifiers in elevator cabins for the improvement of their ventilation effectiveness". Luis Santamaría Bertolín, Jesús Manuel Fernández Oro(*), Katia Argüelles Díaz, Mónica Galdo Vega, Sandra Velarde-Suárez, María Elena del Valle, Luis Joaquín Fernández (2023).
(*) jesusfo@uniovi.es. Fluid Mechanics Area, Department of Energy, University of Oviedo, C/Wifredo Ricart s/n, Gijon, Asturias, 33204, Spain
Published in Journal of Building Engineering, 63 (2023), 105466.
https://doi.org/10.1016/j.jobe.2022.105466

General Information
Name of dataset:
Data from "Optimal position of air purifiers in elevator cabins for the improvement of their ventilation effectiveness"

Name of data files in data set:
'EVO_z1600_C01.txt'
'EVO_z1600_C02.txt'
'EVO_z1600_C03.txt'
'EVO_z1600_C04.txt'
'EVO_z1600_C05.txt'
'EVO_z1600_C06.txt'
'EVO_z1600_C01-INV.txt'
'EVO_z1600_C05-INV.txt'
'SYN_z1600_C01.txt'
'SYN_z1600_C02.txt'
'SYN_z1600_C03.txt'
'SYN_z1600_C04.txt'
'SYN_z1600_C05.txt'
'SYN_z1600_C06.txt'
'SYN_z1600_C01-INV.txt'
'EVO_Infiltrations.txt'
'SYN_Infiltrations.txt'

Dataset language:
English

Date the data set was last modified:
06/10/2021

Funder:
The authors would like to thank the financial support provided by the CDTI, “Centro Tecnológico para el Desarrollo Industrial” from
the Spanish Ministry of Science and Innovation, under the National Strategic Program CIEN, for the granting of the project “INNMEDICAL:
Innovative Medical Industry enabling an Efficient and Autonomous Response against COVID-like Pandemic”. Also the
technical support given by the staff of the TK Elevator Innovation Center, within the framework of the contract CN-21-032-CDTI at the
University of Oviedo, for the development of the study “Optimal Position of the Air Novum device in elevator cabins" is gratefully
acknowledged.

How to cite data:
Data from [article reference]

Methodology for data collection:
Numerical solution of fluid-dynamic variables at particular positions of the study domain, performed with a CFD volume finite-based commercial code (ANSYS Fluent).

Data collector(s):
Jesús Manuel Fernández Oro

Date of data collection:
22/08/2021 - 06/10/2021

Person to contact with questions:
Corresponding author or first autor (see affilations and e-mail in the paper).

Data entry:
25/07/2025

Software (including version #) used to prepare data set:
Matlab 2023b
Excel 365

Data processing that was performed:
Node number, coordinates of every computing cell and values of flow velocity and mean age of air (MAA), named as uds-0-scalar in the files, are stored for different simulation scenarios for both EVO and SYN cabins (two geometries) at the vertical plane z=1.6 m. Cases 1 to 6 (depending on the position of the purifier - see the article for details) and additional inverted configurations are provided in this dataset.
In addition, inlet and outlet flowrates through the small gaps and grilles in both EVO and SYN cabins are given for the different scenarios.

Variables:
Node number [non-dimensional]
x-coordinate [m]
y-coordinate [m]
z-coordinate [m]
velocity-magnitude [m/s]
uds-0-scalar [s]
flow-rate [m3/s]

File Overview:
All files contain the data of #node number (first column), coordinates of the discretized points (second to fouth columns) and values of velocity magnitude and mean age of air (fifth and sixth columns) for all the positions at the z=1.6 m horizontal plane in the different cabins. EVO files are for the large cabin (capacity for 20 passengers maximum) and include around 18,900 points (case-dependent); while SYN files are for the small cabin (capacity for 8 passengers maximum) and include around 17,000 points (case-dependent).
Files with infiltrations provide (in columns) the values of the infiltration flow-rates in the different gaps and grilles of the cabins. In columns, the different locations (see the article for details) and the flow-rates for cases 01 to 06 and also inverted configurations.

Files

EVO_Infiltrations.txt

Files (25.3 MB)

Name Size
md5:1551766e7c4b27a23126a144500ceaeb
1.1 kB Preview Download
md5:093d71ddafe354f7ae127644b70d62d4
1.6 MB Preview Download
md5:c3a928e23f3e46427615b133d04af9f5
1.8 MB Preview Download
md5:e7dad310a161c8c435a35240dc835809
1.8 MB Preview Download
md5:65a9a3ffdc6045bded4136f8cb02dc8a
1.8 MB Preview Download
md5:1c9931f179cd0a5bd2a0e75159e79d5a
1.8 MB Preview Download
md5:cb0f8b4b2ae8983a6d70f7a2f7e8d6ab
1.8 MB Preview Download
md5:1dd385ab98fcabdef2dcc4128c3791d8
1.6 MB Preview Download
md5:9e39ba8b1a01f3ac940dbd09a54f74be
1.5 MB Preview Download
md5:1359c7c1d09b4239e31180e4fd618a77
640 Bytes Preview Download
md5:f23240d20a81e106a10393bd7e2e714c
1.6 MB Preview Download
md5:4ddaac846daf68a36984756acd8206e7
1.6 MB Preview Download
md5:254226bf5a736c66c313f7b36060a030
1.7 MB Preview Download
md5:5065db8df3e47a98ee0e291ca0bb570d
1.6 MB Preview Download
md5:cbad398b28c04a978bd819a24e020916
1.6 MB Preview Download
md5:99f1df77a9a1f25bade912f186d09f4b
1.6 MB Preview Download
md5:71a7437dad49f16d312427ad6e2c0eb7
1.8 MB Preview Download

Additional details

Identifiers

Related works

Is supplement to
Journal article: 10.1016/J.JOBE.2022.105466 (DOI)