This document summarises some of the findings from the EMC-STD project regarding Direct Sampling Time Domain Receivers when used in EMC applications. This includes information about the spectral estimation algorithms, calibration aspects with respect to EMC standardization and performance comparison with more traditional EMI-receivers in both calibration and realistic EMC measurements.