Published October 8, 2025
| Version v1.0.0
Dataset
Open
Microstructure of a graded titanium felt porous transport layer
Authors/Creators
Description
- Felt manufacturer: Sylatech GmbH (Germany)
- X-ray µ-CT device: Procon CT alpha from Procon X-ray GmbH (Germany)
- Acquisation parameters:
- Source voltage: 50 kV
- Current: 160 µA
- Exposure time: 1000 ms
- Number of projections per 360°: 1200
- Image processing steps:
- Image smoothing with mean filter (3 × 3 × 3 kernel)
- Binarization by global thresholding with Otsu method
- Data format: TIFF image stack compressed into ZIP
Further information can be found in Bhaskaran et al. (2022).
Files
img@bin_res1000x950x200_vxl@4x4x4_uint8.tif.zip
Files
(8.0 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:a7676f5d066c7170aadc13c450c61360
|
8.0 MB | Preview Download |
Additional details
Related works
- Is part of
- Journal article: 10.1016/j.ijhydene.2022.07.079 (DOI)