Published February 17, 2015 | Version v1
Software Open

Duck Foot Heat Exchange Model

  • 1. LTU, SWEDEN

Description

The Duck Foot Heat Exchange Model (DFHXM) simulates the start up and steady-state conditions within a duck foot heat exchange system.  The system consists of a heat exchanger and heating reservoir affecting a single flow of fluid.  Fluid enters at a defined temperature and passes through a flat-plate, single-pass countercurrent heat exchanger.  Fluid re-enters the heat exchanger after passing through a heating reservoir and exits the system near its original temperature.  The DFHXM is intended to simulate systems for a variety of pasteurization applications including Legionella eradication and solar water disinfection.

Files

Files (226.3 kB)

Name Size Download all
md5:bc5f6ccbc2f40fe20129fdbe0752f071
226.3 kB Download