Published 1989
| Version v3
Dataset
Open
ALARM (A Logical Alarm Reduction Mechanism)
Description
This synthetic dataset represents alarm message system for patient monitoring. It was introduced in Beinlich et al. (1989).
Task: The dataset collection can be used to study causal discovery algorithms.
Summary:
- Size of collection: 20,000 x 37
- Task: Causal Discovery Problem
- Data Type: Categorical Data
- Dataset Scope: Standalone Dataset
- Ground Truth: Known Graph
- Temporal Structure: Static Data
- License: CC0 (generated for bnlearn)
- Missing Values: No Missing Values
Missingness Statement: There are no missing values.
Collection:
The alarm dataset contains the following 37 variables:
- CVP: Central venous pressure (LOW / NORMAL / HIGH)
- PCWP: Pulmonary capillary wedge pressure (LOW / NORMAL / HIGH)
- HIST: History (TRUE / FALSE)
- TPR: Total peripheral resistance (LOW / NORMAL / HIGH)
- BP: Blood pressure (LOW / NORMAL / HIGH)
- CO: Cardiac output (LOW / NORMAL / HIGH)
- HRBP: Heart rate / blood pressure (LOW / NORMAL / HIGH)
- HREK: Heart rate measured by an EKG monitor (LOW / NORMAL / HIGH)
- HRSA: Heart rate / oxygen saturation (LOW / NORMAL / HIGH)
- PAP: Pulmonary artery pressure (LOW / NORMAL / HIGH)
- SAO2: Arterial oxygen saturation (LOW / NORMAL / HIGH)
- FIO2: Fraction of inspired oxygen (LOW / NORMAL)
- PRSS: Breathing pressure (ZERO / LOW / NORMAL / HIGH)
- ECO2: Expelled CO2 (ZERO / LOW / NORMAL / HIGH)
- MINV: Minimum volume (ZERO / LOW / NORMAL / HIGH)
- MVS: Minimum volume set (LOW / NORMAL / HIGH)
- HYP: Hypovolemia (TRUE / FALSE)
- LVF: Left ventricular failure (TRUE / FALSE)
- APL: Anaphylaxis (TRUE / FALSE)
- ANES: Insufficient anesthesia/analgesia (TRUE / FALSE)
- PMB: Pulmonary embolus (TRUE / FALSE)
- INT: Intubation (NORMAL / ESOPHAGEAL / ONESIDED)
- KINK: Kinked tube (TRUE / FALSE)
- DISC: Disconnection (TRUE / FALSE)
- LVV: Left ventricular end-diastolic volume (LOW / NORMAL / HIGH)
- STKV: Stroke volume (LOW / NORMAL / HIGH)
- CCHL: Catecholamine (NORMAL / HIGH)
- ERLO: Error low output (TRUE / FALSE)
- HR: Heart rate (LOW / NORMAL / HIGH)
- ERCA: Electrocauter (TRUE / FALSE)
- SHNT: Shunt (NORMAL / HIGH)
- PVS: Pulmonary venous oxygen saturation (LOW / NORMAL / HIGH)
- ACO2: Arterial CO2 (LOW / NORMAL / HIGH)
- VALV: Pulmonary alveoli ventilation (ZERO / LOW / NORMAL / HIGH)
- VLNG: Lung ventilation (ZERO / LOW / NORMAL / HIGH)
- VTUB: Ventilation tube (ZERO / LOW / NORMAL / HIGH)
- VMCH: Ventilation machine (ZERO / LOW / NORMAL / HIGH)
Files:
- alarm.csv: dataset
- alarm.bif: Bayesian Network from (Scutari (2010), License CC BY-SA 3.0). The network was used for data generation in Beinlich et al. (1989).
Files
alarm.csv
Additional details
Identifiers
Related works
- Is described by
- Computational notebook: 10.5281/zenodo.15304389 (DOI)
- Is documented by
- Book chapter: 10.1007/978-1-4757-3502-4_6 (DOI)
References
- Beinlich I, Suermondt HJ, Chavez RM, Cooper GF (1989). "The ALARM Monitoring System: A Case Study with Two Probabilistic Inference Techniques for Belief Networks". Proceedings of the 2nd European Conference on Artificial Intelligence in Medicine, 247–256.
- Scutari M (2010). "Learning Bayesian Networks with the bnlearn R Package." Journal of Statistical Software, 35(3), 1–22. doi:10.18637/jss.v035.i03