Published March 20, 2016 | Version v1
Journal article Open

STUDY OF A PASSIVE SOLAR WINTER HEATING SYSTEM BASED ON TROMBE WALL

Description

 buildings for heating and cooling purpose use a large amount of non renewable energy. Now a day�s renewable energy such as solar energy is a suitable solution for reduce the excess use of non renewable energy. Passive solar sy stems do not use the mechanical or electrical equipments to store and transfer the thermal energy. Trombe wall is a passive solar system and it is based on the natural conduction,convection and heat storage. This works contains numerical study on the pass ive solar winter heating system. Study the distrib ution of temperature in wall,living space of room and the effect of outlet position in a system . Analysis can be done for 2 - D model and Present work involves natural ventilation and convective mode of heat t ransfer. Results shows that temperature distributions depend up on the quantity of heat flux gain by Trombe wall and positions of the outlet also affect the performance of the system.

https://www.ijiert.org/paper-details?paper_id=140749

Files

1458725172_Volume 3 Issue 3.pdf

Files (846.4 kB)

Name Size Download all
md5:4e7bfe09ff2196d08e2bdc25b2162336
846.4 kB Preview Download