IODP Site U1537 U-Channel CT Scan DICOM Data, SedCT Output, and HU Values
Authors/Creators
Description
Computed Tomography (CT) Data Collected on IODP Site U1537 u-channel samples using the Oregon State University College of Veterinary Medicine Toshiba Aquillon 64 Slice Medical CT Scanner in collaboration with the Oregon State University Marine and Geology Repository. U-channels were measured in batches of 8 with derived CT data selecting only a portion of these original files for each u-channel. All data are archived in DICOM format and have been processed using SedCT Matlab Tools (Reilly et al., 2017; 10.1002/2017GC006884). Data are reported and descriped by Reilly et al. (2026).
Files Include:
U1537 U-Channel CT DICOM Files (Original).zip
Data in DICOM format from original scans measured in batches of 8. Includes excel spreadsheet with identifying information for which sections were measured in each scan.
U1537A U-Channel CT DICOM Files (Split).zip
Data in DICOM format, segmented so each u-channel is a sperate file. Folder system organized by section with two subfolders included for scans that needed to be run in two scans (nominally sections longer than 1 m). Includes U1537A sections: 24H-2A, 24H-3A, 24H-4A, 25H-3A, 25H-4A, 25H-5A, 25H-6A, 26H-2A, 26H-3A, 26H-4A, 26H-5A, 26H-6A, 26H-7A, 26H-8A, 27F-3A, 2F-4A.
U1537D U-Channel CT DICOM Files (Split).zip
Data in DICOM format, segmented so each u-channel is a sperate file. Folder system organized by section with two subfolders included for scans that needed to be run in two scans (nominally sections longer than 1 m). Includes U1537D sections: 24H-1W, 24H-2W, 24H-3W, 24H-4W, 24H-5W, 24H-6W, 25H-1W, 25H-2W, 25H-3W, 25H-4W, 25H-5W, 25H-6W, 25H-7W, 26H-5W, 26H-6W, 26H-7W, 27H-2W, 27H-3W, 27H-4W, 27H-5W, 27H-6W, 27H-W, 28F-1W, 28F-2W, 28F-3W, 29F-1W, 29F-2W, 29F-3W, 29F-4W, 30F-1W, 30F-2W, 30F-3W, 30F-4W, 31F-1W, 31F-2W, 31F-3W, 31F-4W.
U1537A SedCT Output.zip
CT#s, unscaled TIFF files, and PNG files scaled to 200-1400 HU for U1537A u-channels generated using SedCT Matlab Tools.
U1537D SedCT Output.zip
CT#s, unscaled TIFF files, and PNG files scaled to 200-1400 HU for U1537D u-channels generated using SedCT Matlab Tools.
CTnumbers.zip
CT# data organized for each core into excel spreadsheets.
Files
CTnumbers.zip
Files
(586.3 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:01a728f515fc480617054e9bbf452020
|
45.4 MB | Preview Download |
|
md5:4381b8d45f76cc1398191b12459728d6
|
330.4 MB | Preview Download |
|
md5:d9a7e096a55364678b9339f0ea39486b
|
14.3 MB | Preview Download |
|
md5:ad4d6cda30a6a4dcf353fd362ce142ef
|
33.7 MB | Preview Download |
|
md5:9dc2e0922989added6a8e533300c5847
|
35.9 MB | Preview Download |
|
md5:f149758c5b05e2fe02a9fe59b5c79114
|
126.6 MB | Preview Download |
Additional details
Funding
- U.S. National Science Foundation
- Collaborative Research: Linking Marine and Terrestrial Sedimentary Evidence for Plio-pleistocene Variability of Weddell Embayment and Antarctic Peninsula Glaciation 2114777
- U.S. National Science Foundation
- Collaborative Research: Linking Marine and Terrestrial Sedimentary Evidence for Plio-pleistocene Variability of Weddell Embayment and Antarctic Peninsula Glaciation 2302832
- U.S. National Science Foundation
- A Proposal to Manage the U.S. Science Support Program Office associated with the International Ocean Discovery Program (USSSP-IODP) 1450528
References