Published November 30, 2024 | Version http://impactfactor.org/PDF/IJPCR/16/IJPCR,Vol16,Issue11,Article239.pdf
Journal article Open

Efficacy and Safety of Copper T 380 A as a Contraceptive Method: A Retrospective Study

  • 1. Senior Consultant, Head of Department, Department of Gynaecology and Obstetrics, Koshi Hospital, Biratnagar, Nepal
  • 2. Senior Consultant, Department of Gynaecology and Obstetrics, Koshi Hospital, Biratnagar, Nepal
  • 3. Senior Consultant, Ilam District Hospital, Nepal
  • 4. Consultant, Department of Gynaecology and Obstetrics, Koshi Hospital, Biratnagar, Nepal

Description

Background: The intrauterine contraceptive device (IUCD) after nearly four decades of use is generally recognized as an effective safe economical and useful form of birth control. Its acceptance is worldwide in the developed as well as developing countries. Some of the causes for removal include desire for pregnancy and sterilization etc. Aims of this study: to determine the efficacy of copper T(Cu T) 380A as a contraceptive method, determine the indications of discontinuation of Cu T 380A and identify the difficulties faced during removal in outpatient basis and cases which required removal under anaesthesia in operation theatre. Methods: This Retrospective analysis of Cu T removals was done in Department of Gynaecology and Obstetrics, Koshi Hospital, Biratnagar, Nepal from January 2017 to December 2017. A total number of 256 cases were observed and included in this study. Results: Among the IUCD users, majority belonged to age group of 20 – 30 years. Most of the cases reported for removal came after 2-5 years of usage. Among them, most were referred from periphery in view of difficulty in removal. Out of 256 cases of total Cu T removals, 136 cases(53.1%) were removed on outpatient basis, 120 cases (46.8%) were removed under anaesthesia. Major indication for removal was desire for pregnancy in 198 cases (77.3%), 52 (20.3%) cases were removed for sterilization, 2 (0.78%) case was removed for failure of contraception, 2 (0.78%)case for abnormal uterine bleeding and dysmenorrhea, 2 (0.78%) case for uterine perforation. Conclusion: Copper T is an effective, safe, long-lasting, convenient reversible contraceptive method with very few side effects. The information in this study may be useful to counsel women who are considering the IUCD as a contraceptive method and current users who are requesting for removal due to side effects.

 

 

Abstract (English)

Background: The intrauterine contraceptive device (IUCD) after nearly four decades of use is generally recognized as an effective safe economical and useful form of birth control. Its acceptance is worldwide in the developed as well as developing countries. Some of the causes for removal include desire for pregnancy and sterilization etc. Aims of this study: to determine the efficacy of copper T(Cu T) 380A as a contraceptive method, determine the indications of discontinuation of Cu T 380A and identify the difficulties faced during removal in outpatient basis and cases which required removal under anaesthesia in operation theatre. Methods: This Retrospective analysis of Cu T removals was done in Department of Gynaecology and Obstetrics, Koshi Hospital, Biratnagar, Nepal from January 2017 to December 2017. A total number of 256 cases were observed and included in this study. Results: Among the IUCD users, majority belonged to age group of 20 – 30 years. Most of the cases reported for removal came after 2-5 years of usage. Among them, most were referred from periphery in view of difficulty in removal. Out of 256 cases of total Cu T removals, 136 cases(53.1%) were removed on outpatient basis, 120 cases (46.8%) were removed under anaesthesia. Major indication for removal was desire for pregnancy in 198 cases (77.3%), 52 (20.3%) cases were removed for sterilization, 2 (0.78%) case was removed for failure of contraception, 2 (0.78%)case for abnormal uterine bleeding and dysmenorrhea, 2 (0.78%) case for uterine perforation. Conclusion: Copper T is an effective, safe, long-lasting, convenient reversible contraceptive method with very few side effects. The information in this study may be useful to counsel women who are considering the IUCD as a contraceptive method and current users who are requesting for removal due to side effects.

 

 

Files

IJPCR,Vol16,Issue11,Article239.pdf

Files (512.2 kB)

Name Size Download all
md5:f2c8166e48505d36f7d8923fd5512be6
512.2 kB Preview Download

Additional details

Dates

Accepted
2024-10-26

References

  • 1. Kulier R, O'brien PA, Helmerhorst FM, Usher-Patel M, D'Arcangues C. Copper containing, framed intra-uterine devices for contraception. Cochrane Database Syst Rev. 2007 ;(4):CD005347. 2. Mishra N, Dalal N, Joshi V. Intrauterine Device Insertion during Caesarean Section- A Boon for Rural Women. IOSR J Dent Med Sci. 2013; 8(3):21–3. 3. Singal S, Bharti R, Dewan R, Divya, Dabral A, Batra A. Clinical Outcome of Postplacental Copper T 380A Insertion in Women Delivering by Caesarean Section. J Clin Diagn Res. 2014; 8(9):1–4. 4. Rwegoshora FJ, Muganyizi PS, Kimario GF, Kimario GF. A one-year cohort study of complications, continuation, and failure rates of postpartum TCu380A in Tanzania. Reprod Health. 2017; 17(1):150. 5. Iklaki CU, Agbakwuru AU, Udo AE, Abeshi SE. Five-year review of copper T intrauterine device use at the University of Calabar Teaching Hospital, Calabar. Open Access J Contracept. 2015; 6:143–7. 6. Mutihir JT, Iranloye T, Uduagbgbamen PFK. How long do women use the intrauterine device in Jos Nigeria? J Med Trop. 2005; 7(2):13–9. 7. Rosenberg MJ, Foldesy R, Mishell DR, Speroff L, Waugh MS, Burkman R. Performance of the TCu380A and Cu-Fix IUDs in an international randomized trial. Contraception. 1996; 53(4):197–203. 8. Champion CB, Behlilovic B, Arosemena JM, Randic L, Cole LP, Wilkens LR. A three-year evaluation of TCu 380 Ag and multiload Cu 375 intrauterine devices. Contraception. 1988; 38:631–9. 9. Cheung ML, Rezai S, Jackman JM, Patel ND, Bernaba BZ, Hakimian O, et al. Retained Intrauterine Device (IUD): Triple Case Reportand Review of the Literature. Case Rep Obstet Gynecol. 2018; 2018:9362962. 10. Cetinkaya K, Kumtepe Y, Ingec M. Minimally invasive approach to cases of lost intra-uterine device: a 7-year experience. Eur J ObstetGynecolReprod Biol. 2011; 159(1):119–21.