Clinically significant autoimmune hemolytic anemia with a negative direct antiglobulin test by routine tube test and positive by column agglutination method
Authors/Creators
- 1. MD (corresponding author), Transfusion Center , Catholic University of Sacred Heart , Largo Gemelli 8 00168 Rome , Italy
- 2. MD, Transfusion Center , Rome , Italy
- 3. Chief, Transfusion Center , Rome , Italy
- 4. MD, Clinic of Hematology , Chair of Hematology , Rome , Italy
- 5. PhD, Clinic of Hematology, Chair of Hematology , Catholic University of Sacred Heart , Rome , Italy
Description
Abstract
In two to five percent of cases of autoimmune hemolytic anemia (AIHA), the patient's RBCs are negative in the direct antiglobulin test (DAT). We describe a patient with AIHA with a negative DAT when tested by the traditional tube test but with a strongly positive one when tested by column agglutination. When the DAT was repeated by tube test using 4°C saline washes, it became positive. This phenomenon has been observed when low-affinity antibodies are involved in AIHA. The patient's history and serologic findings are detailed in this report.
Immunohematology 2002;18:109–113.