Published August 16, 2024 | Version v1

A PAINLESS FRACTURE TREATED IN THE EMERGENCY DEPARTMENT

Authors/Creators

Description

Intravenous cannulation is a routine procedure done in healthcare settings to gain access to superficial veinsfor intravenous fluid, medication, and blood product administration. As a rare occurrence, part of the cannula catheter can break and be retained within a vein which may lead to disastrous complications.Here we report a case of a young male, known to be diabetic, who presented to us with a retained foreign body in his forearm causing him a lot of discomfort. On examination in the emergency department, the patient had stable vitals a long, linear, hard object could be palpated under the skin on the radial aspect of the right forearm near the elbow. On taking a detailed history, it was ascertained that the catheter of the cannula had broken during cannula removal and had been retained within the vein. After consent, a procedure under local anaesthesia was performed in the emergency department for the retrieval of the foreign body, with no post-procedure complications. The patient was discharged home in satisfactory condition the same day. This case tells us how a simple routine procedure can get complicated and how early and prompt intervention can avert possible venous embolization of broken segment and sepsis, among other complications.

 

Files

3.pdf

Files (237.1 kB)

Name Size Download all
md5:090fca927cea56ec747c7b1cd613fed9
237.1 kB Preview Download