Published April 21, 2024
| Version v1
Journal article
Open
NAVIGATING SUCCESS: THE IMPACT OF 3D-PRINTED SURGICAL GUIDES IN DENTAL IMPLANT SURGERY
Description
This article explores the significance of 3D-printed surgical guides in dental implant surgery and their impact
on treatment outcomes. Through a comprehensive literature review, the benefits and advancements of utilizing
3D-printed surgical guides are analyzed, highlighting their role in enhancing precision, efficiency, and success
rates in dental implant procedures.
Files
Deutsche internationale Zeitschrift für zeitgenössische Wissenschaft №78 2024-44-45.pdf
Files
(273.4 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:24cce143229333d5a8dc657af46c6810
|
273.4 kB | Preview Download |
Additional details
References
- 1. Resnik R.R. Misch's Contemporary Implant Dentistry. 4th ed. Elsevier; New York, NY, USA: 2020. 2. Tehemar S.H. Factors affecting heat generation during implant site preparation: A review of biologic observations and future considerations. Int. J. Oral. Maxillofac. Implant. 1999;14:127–136. 3. Abuhajar E., Salim N.A., Sallam M., Jarab F., Satterthwaite J.D. The impact of surgical guide design and bone quality on heat generation during pilot implant site preparation: An in vitro study. BMC Oral Health. 2023;23:273. 4. Choi Y.-S., Oh J.-W., Lee Y., Lee D.-W. Thermal changes during implant site preparation with a digital surgical guide and slot design drill: An ex vivo study using a bovine rib model. J. Periodontal Implant. Sci. 2022;52:411–421. 5. Gargallo-Albiol J., Salomó-Coll O., LozanoCarrascal N., Wang H.-L., Hernández-Alfaro F. Intraosseous heat generation during implant bed preparation with static navigation: Multi-factor in vitro study. Clin. Oral Implant. Res. 2021;32:590–597. 6. Jeong S.-M., Yoo J.-H., Fang Y., Choi B.-H., Son J.-S., Oh J.-H. The effect of guided flapless implant procedure on heat generation from implant drilling. J. Cranio-Maxillofac. Surg. 2014;42:725–729. 7. Marković A., Lazić Z., Mišić T., Šćepanović M., Todorović A., Thakare K., Janjić B., Vlahović Z., Glišić M. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites-thermographic analysis on bovine ribs. Vojnosanit. Pregl. 2016;73:744–750. 8. Misir A.F., Sumer M., Yenisey M., Ergioglu E. Effect of surgical drill guide on heat generated from implant drilling. J. Oral Maxillofac. Surg. 2009;67:2663–2668. 9. Dos Santos P.L., Queiroz T.P., Margonar R., de Souza Carvalho A.C., Betoni W., Jr., Rezende R.R., dos Santos P.H., Garcia I.R., Jr. Evaluation of bone heating, drill deformation, and drill roughness after implant osteotomy: Guided surgery and classic drilling procedure. Int. J. Oral Maxillofac. Implant. 2014;29:51–58. 10. Dimitrova, M. Comparative study of linear and volumetric changes of 3D printed and conventional resins in removable prosthodontics [in Bulgarian]. PhD Thesis, 2023, Plovdiv. 11. Stocchero M., Sivolella S., Brunello G., Zoppello A., Cavallin F., Biasetto L. Bone Temperature Variation Using a 3D-Printed Surgical Guide with Internal Irrigation. Appl. Sci. 2021;11:2588.