Published February 28, 2024 | Version http://impactfactor.org/PDF/IJTPR/14/IJTPR,Vol14,Issue2,Article39.pdf
Journal article Open

A Comparative Research between Epidural Analgesia versus Dural Puncture Epidural Analgesia in Labor Analgesia

  • 1. Assistant Professor, Department of Anaesthesiology, Rangaraya Medical College, Kakinada.
  • 2. Resident, Rangaraya Medical College, Kakinada

Description

Introduction: Epidural analgesia (EA) is the gold standard technique; inadequate sacral spread and prolonged labor are the limitations. With this background, a study was conducted to compare the EA with dural puncture EA (DPEA) and 0.125% bupivacaine and fentanyl 1mcg/ml were used. Methods: It was a prospective randomized control study conducted in Andhra Medical College, Visakhapatnam. Pregnant women aged >18 years, ASA grade I and II, singleton studycy with vertex presentation with cervical dilatation of 3 – 5 cm and without any labor analgesia contraindication were included in this research. Non cooperative women, ASA grade III & IV were not considered. The study members were divided in to EA and DPEA groups randomly.  VAS score was used for pain analysis. Time of onset of adequate was taken as the time between initial injections until the VAS score became 3. Fetomaternal hemodynamics were monitored regularly. The labor progress was recorded by serial per vaginal examinations and mode of delivery and complications such as hypotension, pruritis, motor blockade, nausea, and vomiting were recorded. Modified Bromage scale was used for motor blockade analysis considered. APGAR score at 1 min and 5 min was used for neonatal outcome. Unpaired T test, chi square test were used, P value < 0.05 was considered significant. Results: Total 80 members were included, 40 in each group. Statistically there was no significant difference in the mean duration of labor, respectively. Statistically there was significant difference in mean time for onset of adequate anaesthesia and mean duration, respectively. In both the group majority underwent vaginal delivery, no statistical significance. All the neonates in both groups had > 7 APGAR score, statistically not significant. Conclusion: The DPEA technique stands as a secure alternative to EA. The study could be enhanced through the incorporation of noninvasive imaging techniques to visualize the drug spread.

Abstract (English)

Introduction: Epidural analgesia (EA) is the gold standard technique; inadequate sacral spread and prolonged labor are the limitations. With this background, a study was conducted to compare the EA with dural puncture EA (DPEA) and 0.125% bupivacaine and fentanyl 1mcg/ml were used. Methods: It was a prospective randomized control study conducted in Andhra Medical College, Visakhapatnam. Pregnant women aged >18 years, ASA grade I and II, singleton studycy with vertex presentation with cervical dilatation of 3 – 5 cm and without any labor analgesia contraindication were included in this research. Non cooperative women, ASA grade III & IV were not considered. The study members were divided in to EA and DPEA groups randomly.  VAS score was used for pain analysis. Time of onset of adequate was taken as the time between initial injections until the VAS score became 3. Fetomaternal hemodynamics were monitored regularly. The labor progress was recorded by serial per vaginal examinations and mode of delivery and complications such as hypotension, pruritis, motor blockade, nausea, and vomiting were recorded. Modified Bromage scale was used for motor blockade analysis considered. APGAR score at 1 min and 5 min was used for neonatal outcome. Unpaired T test, chi square test were used, P value < 0.05 was considered significant. Results: Total 80 members were included, 40 in each group. Statistically there was no significant difference in the mean duration of labor, respectively. Statistically there was significant difference in mean time for onset of adequate anaesthesia and mean duration, respectively. In both the group majority underwent vaginal delivery, no statistical significance. All the neonates in both groups had > 7 APGAR score, statistically not significant. Conclusion: The DPEA technique stands as a secure alternative to EA. The study could be enhanced through the incorporation of noninvasive imaging techniques to visualize the drug spread.

Files

IJTPR,Vol14,Issue2,Article39.pdf

Files (320.3 kB)

Name Size Download all
md5:ce83af3775b0534f3d4a4b9889fdd7be
320.3 kB Preview Download

Additional details

Dates

Accepted
2024-02-25

References

  • 1. Wang Y, Tzeng JY, Huang Y, Maguire R, Hoyo C, Allen TK. Duration of exposure to epidural anesthesia at delivery, DNA methylation in umbilical cord blood and their association with offspring asthma in Non-Hispanic Black women. Environ Epigenet. 2022; 9(1): dvac026. 2. Czech I, Fuchs P, Fuchs A, et al. Pharmacological and Non-Pharmacological Methods of Labour Pain Relief—Establishment of Effectiveness and Comparison. Int. J Env Res Pub Heal. 2018; 15(12): 2792. 3. Lang D, Long C, Lin S, Xie Y, et al. Satisfaction as a Mediator and Its Interaction With Adherence to Labor Analgesia Protocols: A Cross-Sectional Survey of Chinese Medical Personnel. Front Public Health. 2022; 10:899 515. 4. Zhi M, Diao Y, Liu S, Huang Z, et al. Sufentanil versus fentanyl for pain relief in labor involving combined spinal-epidural analgesia: a systematic review and meta-analysis of randomized controlled trials. Eur J Clin Pharmacol. 2020; 76(4): 501 – 6. 5. Chau A, Bibbo C, Huang CC, Elterman KG, Cappiello EC, Robinson JN, Tsen LC. Dural Puncture Epidural Technique Improves Labor Analgesia Quality With Fewer Side Effects Compared With Epidural and Combined Spinal Epidural Techniques: A Randomized Clinical Trial. Anesth Analg. 2017; 124(2): 560 – 9 6. John A. Thomas, Peter H. Pan, Lynne C. Harris, Medge D. Owen, Robert D'Angelo; Dural Puncture with a 27-Gauge Whitacre Needle as Part of a Combined Spinal–Epidural Technique Does Not Improve Labor Epidural Catheter Function. Anesthesiology 2005; 103:1046– 1051 7. Escalona-Marfil C, Coda A, Ruiz-Moreno J, Riu-Gispert LM, Gironès X Validation of an Electronic Visual Analog Scale mHealth Tool for Acute Pain Assessment: Prospective Cross-Sectional Study. J Med Internet Res. 2020; 22(2): e13468 8. Craig D, Carli F. Bromage motor blockade score – a score that has lasted more than a lifetime. Can J Anesth/J Can Anesth. 2018; 65: 837 – 8. 9. Rao WY, Xu F, Dai SB, Mei Z, Chen XP, Lv CC, Liu CL, Ngan Kee W, Chen XZ. Comparison of Dural Puncture Epidural, Epidural and Combined Spinal-Epidural Anesthesia for Cesarean Delivery: A Randomized Controlled Trial. Drug Des Devel Ther. 2023; 17:2077– 85. 10. Wilson SH, Wolf BJ, Bingham K, Scotland QS, Fox JM, Woltz EM, Hebbar L. Labor analgesia onset with dural puncture epidural versus traditional epidural using a 26-Gauge Whitacre needle and 0.125% bupivacaine bolus: a randomized clinical trial. Anesth Analg. 2018; 126(2): 545 – 51. 11. Yadav P, Kumari I, Narang A, Baser N, Bedi V, Dindor BK. Comparison of dural puncture epidural technique versus conventional epidural technique for labor analgesia in primigravida. J Obstet Anaesth Crit Care. 2018; 8(1): 24 – 8. 12. Hon Sen, Sydney E. Reed, Jennifer E et al. Quality of Labor Analgesia with Dural Puncture Epidural versus Standard Epidural Technique in Obese Parturients: A Double-blind Randomized Controlled study. Anesthesiology 2022; 136:678 – 87. 13. Sharawi N, Williams M, Athar W, et al. Effect of Dural-Puncture Epidural vs Standard Epidural for Epidural Extension on Onset Time of Surgical Anesthesia in Elective Cesarean Delivery: A Randomized Clinical Trial. JAMA Netw Open. 2023; 6(8): e2326710.