Samsung INR21700-50E Capacity and HPPC tests
Authors/Creators
Description
Samsung INR21700-50E Capacity and HPPC tests
Dataset containing 444 samples of Hybrid Pulse Power Cycle (HPPC) tests of Samsung INR21700-50E cells from former micromobility applications. The cells are presorted with different State of Health categories: 95% SoH <= SoH < 100% and 90% <= SoH <= 95%. Furthermore, some new cells were tested for comparison.
The dataset contains charge and discharge tests for 143 cells, combined with a HPPC discharge microcycle at every 10% State of Charge decrement. The remaining cells are tested with a single HPPC microcycle.
The following test protocol was used for the 143 cells:
- Wait until the temperature inside the chamber, reaches thermal equilibrium, i.e., 25 °C
- Charge the cell in CC/CV-mode with C/2 and Icutoff at 98 mA
- Wait at least one hour or until thermal equilibrium
- Discharge the cell with C/5 until 2.5 V is reached (obtain discharge capacity of the cell)
- Wait at least one hour or until thermal equilibrium
- Charge the cell in CC/CV-Mode with C/2 and Icutoff at 98 mA
- Wait at least one hour or until thermal equilibrium
- Perform a HPPC in combination with discharge
- Perform a HPPC micro cycle with SOC at 100 percent (shutdown criteria must be softened for this step)
- Discharge by 10% SOC until 2.5 V is reached
- Perform a HPPC micro cycle (switch polarity after reaching 50% SOC). Stop the cycle if 2.5 V is reached. Wait for 30 minutes after the micro cycle
- Try to discharge until 2.5 V is reached
- Wait until thermal equilibrium is reached
- Charge the cell in CC/CV-mode with ¾ C and Icutoff at 98 mA
Charge and discharge were recorded with 100 Hz. HPPC cycles were recorded with 1 kHz. Temperature was measured at the middle of the cell.
Recorded values: Time [timestamp], ClimaTemp [temperature sensor of climate chamber], I [A, current], Itarget [A, setpoint for current], P [W, power], Q [As, charge, total], Qneg [As, negative charge], Qpos [As, positive charge], Temp[1] [°C, cell temperature], U [V, cell voltage], hp_pulse [variable for start and end of HPPC pulses]
Files
Files
(15.0 GB)
| Name | Size | Download all |
|---|---|---|
|
md5:dab5ffcec8f50bf53a1d67bc703c1699
|
493.1 MB | Download |
|
md5:8852a189a0f00bf86b94b7471719ec97
|
859.8 MB | Download |
|
md5:a61522f0150c27ce00ab750c6ac9c6bf
|
849.5 MB | Download |
|
md5:950bc63df847fc9fc450f08811ca78ca
|
848.7 MB | Download |
|
md5:1cc218fa47d45338ff8068a668d8aa47
|
853.3 MB | Download |
|
md5:96a13ec602b0fea600d7734b1d602de6
|
853.3 MB | Download |
|
md5:164e046752013a72cc4b29188ed8dbb1
|
801.9 MB | Download |
|
md5:e573c0be5acf5bd8e5b3d17719d62a9e
|
860.9 MB | Download |
|
md5:c745ecbc788d5eb106df5cb69ff46f0a
|
753.8 MB | Download |
|
md5:2e0fa58702e78df1763e1463a20c59d5
|
864.1 MB | Download |
|
md5:8942c4aa8412c6789f0502c29423daf8
|
312.9 MB | Download |
|
md5:b7e0ec510e79f49c7bcec60bbe98e853
|
735.2 MB | Download |
|
md5:845bce2dd374b8f8164c1067539239eb
|
838.8 MB | Download |
|
md5:af3515a376dbbe8118cdc3f1ff031f47
|
840.4 MB | Download |
|
md5:69788bf4e5472868592a4093a9df617f
|
849.9 MB | Download |
|
md5:d671641ccc36dd55f859d33834c10f2b
|
847.6 MB | Download |
|
md5:155e81dba4f5f3c139e7b114680fe97a
|
849.3 MB | Download |
|
md5:07a2f41e30e299fc13f8f0e45c16cfe7
|
860.8 MB | Download |
|
md5:902bfb96f9752565afa58925082e351b
|
863.1 MB | Download |
|
md5:b033dabd44b14d3ed1d09c10a6d0da7f
|
40.4 kB | Download |