Published February 9, 2024
| Version 0.2
Dataset
Open
Copper Wire Corrosion and Meteorological Conditions in a Hangar
Description
Measurement of copper wire corrosion in a hangar (Kbely, Prague) with meteorological data (indoor and outdoor temperature, indoor and outdoor humidity, indoor and outdoor dew point, wind direction, wind speed, pressure above mean sea level). The dataset also includes measurements of pollution (SO2) from a meteorological station (Libuš, Prague) and NO2, PM10, and PM2.5 from Holešovice, Prague. The sampling period is one hour, and the measurements were collected for a duration of 390 days.
Files
procraft_corrosion_kbely_data_v02.csv
Files
(2.5 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:b168dba29ba1e01196d31e4a440dea2c
|